Readiness stress-testing of medical AI is extended to open-ended clinical conversation under missing information, where safe behavior means recognizing absent information and qualifying, clarifying, or not over-committing - and where the evaluator becomes part of the measurement.
Abstract
Readiness stress-testing of medical AI has focused on closed-ended and multimodal benchmarks. We extend it to open-ended clinical conversation under missing information, where safe behavior means recognizing absent information and qualifying, clarifying, or not over-committing - and where the evaluator becomes part of the measurement. We stress-test four models - three flagships (Claude Opus 4.8, GPT-5.5, Grok 4.3) and one mid-tier model (Gemini 3.5 Flash) - by deleting the latter half of the final user turn in HealthBench conversations, grading responses with a four-provider LLM-judge panel and a blinded clinician-anchored reference. Two evaluator-facing results are robust. First, judge choice materially changes apparent safety: inter-judge agreement is only moderate (Fleiss'kappa = 0.65), and after adjusting for each judge's general leniency (vote-level logistic regression), a positive same-provider association remains (exact permutation p = 0.04; GPT-5.5 ~ +0.10 on the probability scale) - large enough to change which model appears to over-commit least once its own-provider judge is excluded. Second, LLM judges are more permissive than clinicians on a blinded 50-item subsample: all four are significantly more lenient than the stricter independent clinician (crediting appropriate uncertainty on 66-84% of items vs 52%), and three of four than the author-influenced consensus (Grok directional only; judge-vs-consensus kappa = 0.20-0.43). On the author-audited clinical-underdetermined subset the permissiveness gap widened and the point-estimate model ordering held. A closed-ended MedQA anchor confirms accuracy is high and option-order effects are within a +/-5-point equivalence region for three of four models, so the safety gap is about calibration, not knowledge. We release the harness, prompts, per-item outputs, judge panel, perturbation audit, and human-annotation protocol.
LLM-judged clinical safety effects should be reported as directional and relative, anchored to human review and evaluated jointly with helpfulness, not as calibrated absolute rates.
Overall, while LLM-judges show promise, their inability to handle linguistic and cultural context is a critical limitation, underscoring the need for further investment in scalable evaluation solutions.
G. Williams, S. Rutunda, Floris Nzabakira et al.· npj Digital Medicine· 1 citation
Bottom-up incremental scoring showed the closest alignment with human assessment in clinical AI evaluation, underscoring the need for standardised prompt architectures in clinical AI evaluation.
It is suggested that trustworthy clinical decision support should be evaluated by both average correctness and stability across medically equivalent patient narratives.
No evaluated tool or combination was sufficiently accurate to enable physician-unassisted triage in this setting of patient-initiated text messages in a multi-state Medicaid population.
S. Basu, Sadiq Y. Patel, Parth Sheth et al.· BMC Medical Informatics and...· 0 citations
Consumer artificial intelligence chatbots are now accessed by hundreds of millions of users seeking health information, yet systematic evaluation of their safety boundary maintenance under real-world caregiver pressure remains scarce. We evaluated PediatricSafetyBench-v2, a benchmark of 600 pediatric health queries com...
Vahid Zolfaghari· npj Digital Medicine· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.