A medical model's benchmark score does not establish that the same conclusion holds under a different evaluation. This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold. We audit three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR). Five fixed prompt families yield 244,000 model--image--prompt scores. No model leads every cohort and reliability criterion. Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons. Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.075--0.306 across all four models. On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor; their AUROC point estimates for both named diseases fall below 0.5. CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results. Thresholds chosen for 95\% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations. A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.629 on each of two external cohorts. Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it. These retrospective, single-task results show that discrimination, score reliability and threshold retention support different portability claims. Evidence for chest X-ray tuberculosis screening should identify the complete evaluation specification rather than attribute clinical portability to a checkpoint alone.
This publication proposes a definition and a classification of agile software development approaches and analyses ten software development methods that can be characterized as being "agile" against the defined criterion.
P. Abrahamsson, O. Salo, Jussi Ronkainen et al.· arXiv.org· 727 citations· ⚡54
The study shows that agile practices improve both informal and formal communication, but indicates that, in larger development situations involving multiple external stakeholders, a mismatch of adequate communication mechanisms can sometimes even hinder the communication.
M. Pikkarainen, Jukka Haikara, O. Salo et al.· Empirical Software Engineeri...· 401 citations· ⚡48
The results indicate that software engineering work practices are chosen opportunistically, adapted and configured to provide value under the constrains imposed by the startup context.
Nicolò Paternoster, Carmine Giardino, M. Unterkalmsteiner et al.· Information and Software Tec...· 394 citations· ⚡54
The possibility of inferring high-dimensional data inference in a model that consists of a prior and an auxiliary differentiable constraint given some additional information is considered, thereby allowing a range of potential applications in adapting models to new domains and tasks.
Alexandros Graikos, Esmeralda S. Whitammer, N. Jojic et al.· Neural Information Processin...· 316 citations· ⚡15
Radiology AI is evolving beyond report generation. CARE-X explores a unified approach that combines flexible reasoning, calibrated predictions, and measurement-based tools for chest X-ray interpretation. The post Introducing CARE-X: Towards Clinically Useful Radiology VLMs with Auxiliary Supervision, Reward-Aligned Learning, and Tool-Augmented Measurement appeared first on Microsoft Research.