2026· E3S Web of Conferences· Vol 729, pp. 01004· 0 citations· 6 references
Abstract
Power system blackouts remain a significant grid reliability threat, often resulting from cascading failures triggered by faults, operational errors, extreme weather conditions or cyberattacks. This study investigated the mechanism of power system blackouts and evaluated practical prevention strategies aimed at improving power system resilience. Historically significant blackout events were analysed to identify common failure patterns and key lessons for modern grid operation. A simulation-based approach was adopted using an IEEE 9-bus test system on DigSilent Powerfactory to analyse cascading failures under generator outage conditions. The effectiveness of load reduction and battery energy storage systems (BESS) was assessed using frequency and voltage stability metrics. The simulation results showed that the loss of generator 3, representing approximately 26.6 % of total generation capacity, resulted in voltage and frequency instability that met the study’s blackout criteria. Under the load reduction scenario, voltage was restored with a minimum voltage of 0.9515 p.u. and frequency nadir of 49.747 Hz, whereas BESS support achieved faster voltage recovery (4s versus 6s) while maintaining full load supply. These findings demonstrate that BESS provides more effective blackout mitigation strategy than conventional load reduction and can significantly enhance power system resilience.
The rapid integration of renewable energy sources into modern electrical power systems has created new operational challenges for transmission system operators worldwide. Renewable energy sources such as solar and wind power are inherently intermittent and weather-dependent, causing fluctuations in power generation tha...
Irfan Shaqiri· INTERNATIONAL CONGRESS FROM...· 0 citations
In recent years, power grids have grown increasingly complicated, and the rising penetration of new energy sources poses prominent risks to the secure and stable operation of power systems. As a critical technology for improving grid resilience and power supply reliability, mobile operation and maintenance bases are in...
Jun-Jie Zhang, Zi-Ping Peng, Gang Chen et al.· Processes· 0 citations
Over the years, Dominion Energy Virginia (DEV) has experienced recurring power quality disturbances, including voltage and power oscillations, particularly in areas with significant inverter-based generation. While these phenomena suggest a potential relationship to system strength, no definitive correlation has yet be...
Mohammed N. Khamees, G. Ilunga, Zhong-Xia Zhang et al.· 0 citations
Micro-grids often use a combination of a battery and a grid-forming inverter to reduce the dependency of a grid segment on a constant power supply. Because these systems offer a high resilience against blackouts, it is expected that their numbers will grow in the coming years.This paper presents the Resilience-Monitor,...
Philip Weber, B. Wille-Haussmann, J. Ungerland et al.· 2026 International Conferenc...· 0 citations
The increasing electricity demand presents significant challenges for the power system in maintaining stable and reliable operation. These challenges place stress on electrical power grids, particularly the distribution system, and may lead to power disruptions and blackouts if not managed effectively. This research fo...
Nurfaraliyana Samburi, Ahmad Fateh Mohamad Nor, S. Salimin et al.· ASEAN Engineering Journal· 0 citations
In recent years, wind power generation has attained significant attention, leading to the
installation of numerous wind power plants worldwide. Most wind turbines employ
induction generators, which typically absorb substantial reactive power (VARs) from the
grid. This reactive power demand can result in voltage drops a...
K. Archana, V. Pushparajesh· ITEGAM- Journal of Engineeri...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.