Skip to content
Open access

Objective Assessment of Intermittent Exotropia Magnitude and Control Using the Binocular Eye Alignment Monitor.

Sep 2026 · Ophthalmic & physiological optics · 0 citations · 10 references
Medicine

TL;DR

The notable differences in control observed with the BEAM compared to current clinical measures suggest that office control scores and prolonged objective monitoring may capture different aspects of IXT control.

Abstract

Purpose

To compare an objective assessment of intermittent exotropia (IXT) control and deviation size using the binocular eye alignment monitor (BEAM) to standard clinical assessments.

Methods

IXT control and deviation size were evaluated in 15 participants aged 8-35 years. Participants completed two visits that included a 90-min BEAM eye movement recording at a distance (6 m) to evaluate distance IXT size and control of the deviation objectively. IXT control was assessed using the mean of three measurements of the IXT Office Control Scale, and the deviation size was measured with the prism alternate cover test (PACT).

Results

The mean IXT control score in the IXT participants was 2.2 ± 1 points, which was weakly correlated with the percentage of time strabismic as measured by the BEAM (Spearman's correlation coefficient = 0.29; p = 0.30). Distance PACT and mean BEAM deviation size demonstrated a moderate, non-significant association (ρ = 0.47, p = 0.08). BEAM measurements were consistently smaller than PACT measurements. IXT distance control (0.44; 95% CI: 0.04-0.80; p = 0.03) and the median deviation size measured by the BEAM (z = -2.1, p = 0.03) were significantly different between visits 1 and 2 (z = -2.1, p = 0.03); however, the percentage of time deviated (BEAM) was not significantly different between the two study visits (z = -0.63; p = 0.50).

Conclusions

The notable differences in control observed with the BEAM compared to current clinical measures suggest that office control scores and prolonged objective monitoring may capture different aspects of IXT control. Objective monitoring over extended periods may be a valuable complement to traditional clinical assessment in both research and clinical care.

Read PDF

Similar papers

Sep 2026

Comparing the Single Maddox Rod Test to the Alternate Cover Test in Normal Individuals.

PURPOSE The single Maddox rod test (SMRT) is a rapid subjective method for detecting ocular misalignment. In this study, we compared the prism single Maddox rod test (PSMRT) to the prism alternate cover test (PACT) in normal individuals to see if there was any disagreement. METHODS Ocular alignment was measured at di...

Victoria Erickson, K. Merrill, Collin M. McClelland et al. · 0 citations
Open access Oct 2026

Effect of Working Distance on Wesson Card Fixation Disparity and Its Clinical Predictors in Symptomatic Patients

Aim: Fixation disparity (FD) is a sensitive marker of binocular vision stress and is often assessed in patients with asthenopia. Working distance alters accommodative and vergence demands. However, its effect on FD under routine clinical settings is not well established. Purpose: To investigate the effect of working di...

T. I. Metsing, G. Tamenti · 0 citations
Open access Sep 2026

Impact of preoperative deviation control on one-year motor results after intermittent exotropia surgery

In the overall cohort, surgical success was not significantly associated with preoperative control status, age at surgery, age at onset, CDVA, refractive characteristics, amblyopia, anisometropia, deviation magnitude, laterality, and the surgical procedure (all P > 0.05).

Alaa Alghurab, M. Akbari, S. Naroo et al. · 0 citations
Open access Aug 2026

Evaluation of a new clinical test protocol for pointing acuity - An initial validity study

Sensorimotor control of the arm and hand can be disturbed in various health conditions causing deviant and unfavourable movement patterns. This study aimed to evaluate a new clinical test protocol for pointing acuity using the Leap Motion Controller (LMC) and assess the concurrent validity against a standard laboratory...

Benjamin Hägglund, Johan Jirlén, C. Brogårdh et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.