Skip to content
Conference

Analysis of Lightning Protection Performance between Externally Gapped Line Arrester (EGLA) And Non-Gapped Line Arrester (NGLA) On Distribution Networks in High Lightning Density Areas

Aug 2026 · 2026 7th International Conference on Power Engineering and Renewable Energy (ICPERE) · pp. 327-331 · 0 citations · 10 references

Abstract

Lightning strikes are a primary factor contributing to temporary overvoltages in electrical distribution networks, especially in Medium Voltage Overhead Lines (MVOL). Such overvoltages can cause insulation breakdown, significantly impairing the reliability of the system. The purpose of this research is to evaluate the effectiveness of lightning protection by contrasting Non-Gapped Line Arresters (NGLA) with Externally Gapped Line Arresters (EGLA), while also identifying the most efficient setup. The approach involves conducting electromagnetic transient simulations using ATPDraw across four different scenarios: a system without protection, a setup with parallel NGLA, a scenario featuring series EGLA, and a combination approach. The factors assessed include residual voltage and Protective Margin (PM). The findings reveal that the unprotected configuration presents a high level of risk, with residual voltage surging to 145. 5 kV, resulting in immediate flashover. Utilizing NGLA brings the residual voltage down to 121. 7 kV; nonetheless, it achieves only a 19% PM, which is inadequate to avert premature backflashover. On the other hand, the EGLA setup exhibits better protective capabilities, clipping the surge waveform early at 105. 4 kV and yielding a secure PM of 30%. The study concludes that EGLA offers a markedly more efficient and dependable lightning protection option for 20 kV distribution systems when compared to NGLA.

View source

Similar papers

Open access Aug 2026

Feasibility Study of Lightning Arresters Default Detector on the 20 kV Distribution Network of the Lengkese Feeder, PT PLN (Persero) ULP Takalar

Lightning arrester is one of the protection equipment in the medium voltage distribution network that functions to protect transformers and electrical equipment from overvoltage due to lightning strikes or surges. As the operating life increases, the lightning arrester can experience insulation degradation which is cha...

Iswandi Najamuddin, Massikki Massikki, Firdaus Firdaus et al. · 0 citations
Open access Aug 2026

An Improved Electro-Geometric Model for The 150 kV Kenten–Tanjung Api-Api High-Voltage Overhead Line (Sutt) to Enhance The Performance of The Lightning Protection System

Lightning strikes remain one of the major causes of disturbances in high-voltage overhead transmission lines, particularly in tropical regions with high lightning activity, such as Indonesia. Failures caused by shielding failure and back flashover can reduce transmission reliability and lead to operational disruptions....

Salhadi Prataba, R. Yasser, Rudy Setiabudi · 0 citations
Review Open access Aug 2026

Comparison of the Lightning Performance Between the Poles of the Inga–Kolwezi ±500 Kv Hvdc Lines

High-voltage direct-current (HVDC) transmission schemes are designed for high transfer capability and long-distance delivery. Still, their reliability can be significantly affected by lightning, as even relatively infrequent lightning faults can interrupt large power transfers. This study examines the lightning perform...

Mizengi Léon Mwanda, André Mampuya Nzita · 0 citations
Conference Open access Sep 2026

Research on the insulation ground wire gap switching device for transmission lines assisted by unmanned aerial vehicles

To address the inherent contradiction in the required parallel gap distance of transmission-line insulated ground wires under lightning protection and ice-melting conditions, as well as the high safety risk and low operational efficiency associated with conventional manual gap adjustment methods, this paper proposes a...

Feng Xiao, Kai Xun, Xin-Min Li et al. · 0 citations
Open access Sep 2026

Analysis of VFTO and Its Mitigation in a GIS through Additional Earthing Grid

Very Fast Transient Overvoltages (VFTOs) are one of the major insulation stress phenomena encountered in Gas Insulated Substations (GIS). VFTOs are generated primarily during disconnector switching operations and are characterized by extremely steep wavefronts, high frequency oscillations, and short durations. These tr...

M. Prabhakar, V. Anil, I. Chandramouli et al. · 0 citations
Open access Sep 2026

Mitigating dynamic insulation breakdown in iced overhead ground lines: A differentiated dielectric shielding method with sequential electro-mechanical coupling analysis

In regions prone to severe icing, the nonlinear spatial galloping of overhead transmission lines can induce dynamic instability in conductor-to-ground wire clearances, leading to transient insulation breakdown. To address this dynamic dielectric failure mechanism, this paper proposes a novel differentiated insulation p...

Yi Tian, Jia-Wei Xu, Shang Gao et al. · 0 citations