This work presents a new B1 + and B1 - model-based fitting approach for interferometric presaturated TurboFLASH data, which improves B1 + and B1 - mapping robustness to noise and enables more flexible satTFL acquisition scheme, allowing better trade-offs between accuracy and scan time.
Abstract
Purpose
Transmit (B1 +) and receive (B1 -) sensitivities of parallel-transmit/receive RF array are a prerequisite for modern ultra-high-field MRI. Their accurate mapping remains challenging for coils with high transmit dynamic range, particularly in regions with low combined-mode B1 + magnitude, where standard reconstruction is impaired by noise. This work presents a new B1 + and B1 - model-based fitting approach for interferometric presaturated TurboFLASH (satTFL) data. With an optimized acquisition scheme, this method improves B1 +/B1 - mapping accuracy.
Methods
Voxel-wise B1 + and B1 - are expressed as the product of a complex unit-norm vector (phasor) and a scalar (efficiency). Phasors are estimated through singular value decomposition of satTFL signals, and efficiencies are recovered with fitting to the signal equation. This method was evaluated in phantom simulations for 7 T and 11.7 T 8Tx/32Rx RF arrays and compared with standard approaches. As it supports a variable number of pre-saturated scans, different interferometric schemes were optimized for B1 + accuracy. Finally, schemes yielding acceptable B1 + error with minimal acquisition time were tested in vitro at 7 T and 11.7 T and in vivo at 7 T.
Results
The proposed method provided lower median B1 + and B1 - errors than conventional satTFL methods and fewer outliers; the number of voxels with error > 30% is reduced from several dozens to zero. In vitro results were consistent with the simulations, and in vivo maps demonstrated good quality.
Conclusion
The proposed method improves B1 + and B1 - mapping robustness to noise and enables more flexible satTFL acquisition scheme, allowing better trade-offs between accuracy and scan time.
The proposed dual-echo bSSFP/bDESS method provides a high-SNR and time-efficient strategy for sequence-specific T2-sensitive contrast characterization at ultra-low field.
Sheng Shen, Neha Koonjoo, Hester A. Braaksma et al.· IEEE transactions on bio-med...· 0 citations
BACKGROUND
Accurate quantification of intravoxel incoherent motion (IVIM) parameters on the magnetic resonance linear accelerator (MR-Linac) is challenging due to low signal-to-noise ratio and time constraints.
PURPOSE
This study aimed to evaluate the impact of b-value acquisition strategies and estimation algorithms...
Xin-Xiang Zhou, N. Huang, Zeng-Yi Fang et al.· Physica medica (Testo stampa...· 0 citations
Subject motion and gradient heating-induced frequency and phase offsets result in spectral misalignment during single-voxel MR spectroscopy (SVS) acquisitions. Several methods have been presented to align the spectra, but their performance on a 7T system is unclear. This study aimed to evaluate the practical importance...
Chu-Yu Lee, Jia Xu, Bao-Lian Yang et al.· bioRxiv· 0 citations
The Iseult scanner delivered the first human brain images at 11.7 T. Here, we bring forth the design of the RF coil used for these acquisitions, featuring 8 transmit and 32 receive channels, then evaluate its SNR and g‐factor advantages with respect to a similar coil at 7 T. We attempt a deduction of the SNR dependency...
Alexis Amadon, Paul-François Gapais, G. Ferrand et al.· NMR in Biomedicine· 0 citations
BACKGROUND/PURPOSE
Simultaneous T1/T2 mapping with hybrid (mixed) sequences has been proposed, but clinical use is limited by long acquisition times. Accelerated reconstruction-parallel imaging (PI; SENSE), compressed sensing (CS), and deep learning (DL)-allows shorter scans but may alter quantitative values and image...
M. Kanamoto, Yuki Matta, Toshiki Tateishi et al.· Magnetic Resonance Imaging· 0 citations
PURPOSE
To develop a technique for joint measurement of fat and water-specific longitudinal relaxation rates (R1f and R1w), effective transverse relaxation rate (R2∗), and proton density fat fraction (PDFF) combining the Multi-Echo Magnetization Prepared Two Rapid Acquisition of Gradient Echoes (ME-MP2RAGE) sequence an...
Jorge Campos Pazmiño, Marc-Antoine Fortin, Véronique Fortier et al.· Magnetic Resonance Imaging· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.