Skip to content
Preprint

CTrex: A Research-Oriented Framework for Kernel- and Projection-Level Algorithm Development in CT Reconstruction

Sep 2026 · 0 citations · 25 references
Physics

TL;DR

CTrex is introduced, a research-oriented, GPU-accelerated iterative reconstruction framework that exposes the projection-correction-backprojection pipeline down to the kernel level and allows non-ideal acquisition effects to be incorporated directly into the numerical operators rather than treated as external corrections.

Abstract

Micro-computed tomography (micro-CT) is increasingly applied to imaging scenarios in which object motion, deformation, truncated fields of view, continuous rotation, or unconventional scanning protocols violate assumptions underlying classical reconstruction pipelines. Existing reconstruction frameworks efficiently support standard geometries and workflows but offer limited control over how projection operators are discretized and evaluated. This restricts methodological exploration when accuracy depends on ray sampling, interpolation, or operator coupling. We introduce CTrex, a research-oriented, GPU-accelerated iterative reconstruction framework that exposes the projection-correction-backprojection pipeline down to the kernel level. Rather than treating these operators as fixed black boxes, CTrex represents them as editable computational building blocks within a unified iterative structure. This allows non-ideal acquisition effects to be incorporated directly into the numerical operators rather than treated as external corrections. CTrex combines GPU-level accessibility with an extensible geometry formulation based on homogeneous-coordinate view matrices, allowing rigid and affine transformations, detector misalignments, and time-varying geometries to be expressed consistently. It supports circular, helical, offset, and conveyor-belt trajectories while keeping GPU kernels agnostic to the trajectory definition. Applications in motion- and deformation-aware reconstruction, event-based 4D imaging, cylindrical-coordinate reconstruction, and extended-field-of-view CT illustrate how operator-level adaptations enable strategies difficult to realize in conventional frameworks. CTrex provides a flexible platform for CT reconstruction research under realistic and unconventional imaging conditions.

View source

Similar papers

Preprint Aug 2026

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

This work investigates whether a single diffusion model trained across several imaging domains can instead serve as a prior for many CT problems simultaneously, and proposes a frozen model that out-performs analytic reconstructions in all three cases.

Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman et al. · 0 citations
#artificial intelligence Preprint Sep 2026

Field-of-View Extension in Dental Cone-Beam CT via Implicit Neural Representations and Diffusion Model-Based Refinement

A three-stage framework that consists of an implicit neural representation (INR) for estimating missing parts of the truncated projection data, an iterative reconstruction for generating a secondary volumetric image with improved anatomical consistency and a fast diffusion model for image enhancement is proposed.

Susanne Schaub, Florentin Bieder, Matheus L. Oliveira et al. · 0 citations
Preprint Sep 2026

Model-Based Iterative Reconstruction with View-Dependent Detector Displacements for Cone-Beam CT

Detector shifting is used in industrial cone-beam computed tomography to reduce ring artifacts, but the resulting detector motion can vary nonuniformly across projection views and produce detector positions that cannot be represented by fixed offsets. Although analytical reconstruction can accommodate this motion, appr...

Doga Topcicek, Sharmin Majumder, Whitney A. Poling et al. · 0 citations
Preprint Aug 2026

Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction

LiftXR is proposed, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction, and consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art.

Yi-Fei Wu, Yi-Cheng Wu, Qiang Ma et al. · 0 citations
Open access Aug 2026

Memory-efficient image reconstruction using diffusion models for accelerated 3D non-Cartesian UTE imaging.

A novel, memory-efficient image reconstruction framework using score-based diffusion models tailored for highly undersampled 3D radial UTE acquisitions is proposed that enables robust and high-fidelity reconstructions from as few as 4000 spokes-representing up to 50 × undersampling relative to Nyquist.

Jonas Petersen, Stefan Sommer, Thomas Küstner · 0 citations
#artificial intelligence Preprint Aug 2026

Physics-Guided Flow Matching for CT Image Reconstruction

Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps.

Davide Evangelista · 1 citation

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.