Aug 2026· Radiation· Vol 6, pp. 32· 0 citations· 31 references
TL;DR
The auxiliary device developed in this study allows for consistent detector angle maintenance and fixation during hip joint axiolateral projection, thereby improving reproducibility and ease of examination, and suggests its potential usefulness for achieving more accurate imaging in clinical settings.
Abstract
This study aimed to evaluate the utility of a 3D-printed, weight-bearing auxiliary device designed to improve reproducibility and facilitate detector fixation during axiolateral radiography of hip joints known to be affected by inter-operator variability. The experiment was conducted using a radiolucent human phantom. Multiple radiographs were taken under identical conditions. Reproducibility and utility were assessed by measuring the α angle and off-set ratio from acquired images. Results showed that the mean α angle was 51.58° (±5.14°) with the auxiliary device and 50.45° (±4.90°) without it, with no statistically significant difference between conditions (Wilcoxon signed-rank test, p = 0.2024), indicating no measurable improvement in reproducibility. The off-set ratio likewise did not differ significantly between conditions (p = 0.1704). However, using the device did not significantly affect the off-set ratio. In conclusion, the auxiliary device developed in this study allows for consistent detector angle maintenance and fixation during hip joint axiolateral projection, thereby improving reproducibility and ease of examination. This suggests its potential usefulness for achieving more accurate imaging in clinical settings.
Unicompartmental knee arthroplasty (UKA) is an effective treatment for medial compartment knee osteoarthritis, with its outcomes highly dependent on the accuracy of prosthesis positioning. Conventional UKA, performed using traditional instrumentation, often relies heavily on surgical experience and may lead to variabil...
Kun Zhang, Jin-Hua Zhang, Shang Gao et al.· 3D Printing in Medicine· 0 citations
Objective To evaluate the feasibility and clinical efficacy of patient-specific 3D-printed guide plates for pedicle screw placement in the upper cervical spine, compared with the conventional free-hand technique. Methods A retrospective analysis was conducted on 39 patients who underwent upper cervical spine surgery be...
Guo-Qi Niu, Ya-Long Guo, Gong Zhou et al.· Frontiers in Neurology· 0 citations
Objective: To evaluate the effect of printing orientation on the dimensional accuracy, trueness, and 9-month stability of two 3D-printed dental resins.
Methodology: In this in vitro study, 108 specimens of Model Resin Material (MRM) and Interim Prosthesis Material (IPM) were printed at 0°, 45°, and 90° (n=9/group). Sp...
Shilan H. Fatah, B. Selivany, N. Martani· Rawal Medical Journal· 0 citations
The objective was to evaluate the trueness of interocclusal registration obtained with three intraoral scanning systems versus a conventional impression and bite registration in fully dentate patients. Twenty adults with complete dentitions and Angle Class I occlusion were enrolled. Complete-arch scans were obtained wi...
Felix Förtsch, J. Ries, Tom Kasperlik et al.· Bioengineering· 0 citations
Background: Accurate determination of sagittal condylar inclination (SCI) and Bennett angle (BA) on a semi-adjustable articulator plays a crucial role in ensuring prosthodontic stability and occlusal harmony. However, quantitative data regarding the repeatability and reproducibility of this manual adjustment protocol i...
Bình Thanh Trần, Tra Thu Nguyen, Linh Khanh Trinh et al.· VNU Journal of Science Medic...· 0 citations