Introducing DIANA: dual-mode imaging analysis open-source simulation software

Aug 2026 · Scientific Reports · Vol 16 · 0 citations · 43 references
Medicine

TL;DR

DIANA (Dual-mode Imaging Analysis), an open-source Python package that implements a complete dual-modality CT simulation pipeline, is presented and demonstrated on a simple composite phantom and a clean, high resolution study of a realistic lithium-ion cell.

Abstract

The use of the complementarity of the contrast between X-rays and neutrons for computed tomography is a well-established technique. X-rays are strongly attenuated by dense, high-atomic-number materials, while neutrons are particularly sensitive to light elements, such as hydrogen or lithium. Combining the information of both modalities into a two-dimensional histogram allows for the discrimination of material phases that would otherwise not be distinguishable with a single technique alone. Here we present DIANA (Dual-mode Imaging Analysis), an open-source Python package that implements a complete dual-modality CT simulation pipeline. The current version of the software builds a voxelised phantom, creates the radiographic projections for polychromatic X-rays and monochromatic neutrons, performs controlled artifact injection and reconstruction, and finally handles the visualisation of the 2D histogram and its analysis with both shape and quality metrics. To show the capabilities of DIANA, we demonstrate the application on a simple composite phantom and a clean, high resolution study of a realistic lithium-ion cell. The architecture of the package is extensible toward other modalities, such as polarised neutrons, phase-contrast X-rays or energy-resolved neutrons, among others. The package is hosted on Github under an MIT licence.

Read PDF

Similar papers

Preprint Oct 2026

Monte Carlo Framework for Physics-Based Design and Optimization of X-Ray Compressive Ghost Imaging Systems

X-ray ghost imaging has emerged as a promising computational imaging modality capable of forming images from spatially integrated measurements. Unlike optical implementations, image formation is governed by multiple energy-dependent photon-matter interactions: photoelectric absorption, Compton scattering, and fluoresce...

R. H. Shukrun, A. Ben Yehuda, Y. Korotinsky et al. · 0 citations
Open access Nov 2026

Virtual X-ray Tomography as a Digital Twin for NDT and Synchrotron Imaging

X-ray computed tomography (XCT) is increasingly used in non-destructive testing (NDT) to inspect complex material combinations and various components. However, the growing complexity of XCT systems and inspection tasks makes experimental planning, parameter optimisation, and result interpretation both time-consuming an...

Franck P. Vidal, E. Andreasson, Kajsa Fahlgren et al. · 0 citations
Open access Nov 2026

MIR2-Toolkit: a Python program for multiple-image radiography analysis with integrated silicon-crystal diffraction modeling tools.

Analyzer-based multiple-image radiography (MIR) is an X-ray phase-contrast imaging technique. It retrieves absorption, refraction, and ultra-small-angle X-ray scattering signals using the angular selectivity of a perfect-crystal analyzer. Conventional MIR processing typically relies on normalization between the object...

Farangis Foroughi, D. Krapohl, B. Norlin et al. · 0 citations
Open access Oct 2026

Diffuse environment imaging via non-ionising optical tomography and inverse Radon reconstruction

Non-ionising optical tomography offers a safer alternative to traditional imaging techniques for radiation-sensitive biological and, particularly, human tissues. In this study, we developed a laser scanning system incorporating axial, transverse, and rotational motion to acquire projection data from optically heterogen...

C. Merx, G. Sharafutdinova, Renee V. Goreham et al. · 0 citations
Oct 2026

Unified Projection-Domain Material Decomposition for Energy-Integrating and Photon-Counting CT.

OBJECTIVE To develop a unified and efficient method for projection-domain material decomposition in spectral computed tomography (CT) that incorporates an arbitrary number of spectral measurements, independent of the acquisition mechanism, without reducing the measurements to two effective energies. APPROACH A nested...

Dale Black, Surya Naidu, H. Khodajou-Chokami et al. · 0 citations
Open access Nov 2026

OpenTOPAS-SPECT: an extension for full-physics clinical and preclinical SPECT simulation.

OBJECTIVE Single-photon emission computed tomography (SPECT) simulations must resolve collimator transport, detector energy deposition, and low-efficiency projection formation within one model. General transport codes leave users to build the imaging components, whereas dedicated SPECT codes offer efficient camera mode...

Víctor Valladolid-Onecha, Alejandro Bertolet · 0 citations