Aug 2026· Medical Physics (Lancaster)· Vol 53· 0 citations· 52 references
Medicine
TL;DR
A deformable image registration (DIR) framework is developed that integrates inverse consistency with local biomechanical constraints, enabling tissue‐specific motion modeling using contours from only a single image volume, yielding anatomically plausible motion estimates for ART workflows.
Abstract
Abstract Background Accurate motion estimation remains a key challenge in adaptive radiotherapy (ART). Voxel‐wise accuracy is required, as registration errors can compromise the treatment quality. Locally constrained image registration is a promising technique to further improve ART treatment, but relies heavily on quick and accurate delineations of the local areas used to constrain. In online clinical scenarios, these delineations are often available on pre‐treatment image volumes, but not on the online data due to accuracy and time constraints. Purpose We developed a deformable image registration (DIR) framework that integrates inverse consistency with local biomechanical constraints, enabling tissue‐specific motion modeling using contours from only a single image volume. This approach enforces tissue‐specific constraints on the inverse deformation field and propagates them to the forward deformation through inverse consistency optimization, yielding anatomically plausible motion estimates for ART workflows. Methods The proposed framework was evaluated in three scenarios relevant to ART: abdominal CT‐CT and multi‐modality CT‐MR registration with incompressibility constraints on the liver and kidneys, as well as thoracic CT‐CT registration with local rigidity constraints on the ribs and vertebrae. We also investigated the robustness of the framework to image degradation by evaluating motion estimates under added Gaussian noise and artificially induced streaking artifacts. Performance was compared to a baseline DIR model and an unconstrained inverse‐consistent model. Accuracy and anatomical consistency were assessed using landmark alignment, contour overlap, and physics‐based motion analysis. Results We demonstrate that local biomechanical constraints imposed on the inverse deformation field are successfully propagated to the forward motion field through inverse consistency optimization. The proposed framework improves the biomechanical plausibility of the resulting deformation fields at a small cost of landmark‐based accuracy, and maintaining comparable results in terms of contour‐based evaluation. The method is applicable to both mono‐ and multimodality registration and is more robust to noise and artifacts that appear from image acquisition and reconstruction. Conclusions The proposed framework uses inverse consistency to propagate local constraints between motion fields. This work demonstrates the use of local biomechanical constraints for DIR in several use‐cases for ART. This methodology requires delineations of local tissue on only one of the image volumes. This approach can become beneficial for applications where voxel‐wise accuracy and anatomical consistency are required, but quick and accurate delineations of new anatomies are unavailable, such as online ART.
This study proposes a training-free two-stage optimization framework for accurate 3D reconstruction of volumetric medical images, offering a precise, generalizable solution for surface reconstruction of volumetric medical images.
Jing Shi, Xian-Yue He, Si-Chun Chen et al.· Medical and Biological Engin...· 0 citations
The DART method improves efficiency by reducing unnecessary imaging and replanning when the treatment remains robust against anatomy changes, and helps determine whether a patient would benefit from adaptive replanning.
Jessica Lye, Kartik Kumar, B. Harris et al.· Journal of Applied Clinical...· 0 citations
Evaluating whether an MRI‐only workflow, using commercial AI models for segmentation and sCT generation (MVision), demonstrates performance comparable to expert‐defined segmentations and reference CT‐based calculations within the studied dataset confirms that an AI‐segmentation and MRI‐sCT workflow provides geometric,...
Amanda Östensson, J. Jonsson· Journal of Applied Clinical...· 0 citations
OBJECTIVE
Supervised synthetic computed tomography (sCT) generation from cone-beam CT (CBCT) requires spatially registered training pairs, yet perfect registration between separately acquired scans is unattainable. This registration bias propagates into trained models and corrupts intensity-based evaluation, so higher...
L. Zimmermann, Michael Rauter, Martin Buschmann et al.· Physics in Medicine and Biol...· 0 citations
It is suggested that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation, because accurate registration is a prerequisite for deformable dose accumulation.
Hengjie Liu, Manju Sharma, Xinyi Fu et al.· 0 citations
DINE is applied to two registration backbones, Robust-DefReg and DefTransNet, using a two-stage strategy: a first-stage model is trained with Chamfer distance, its predicted deformation fields are used to estimate a prior, and the model is then refined with a combined distance and negative log-prior objective.
Sara Monji-Azad, Rohit Beer, M. Kinz et al.· arXiv.org· 1 citation
We use cookies to run the site and, with your consent, for analytics and to show ads.