Evaluation of the Influence of Tantalum on the Microstructural, Mechanical and Electrochemical Properties of Ti–Mo–Zr–xTa Alloys for Use in Biomedical Devices
Sep 2026· Journal of Functional Biomaterials· Vol 17, pp. 434· 0 citations· 52 references
Medicine
TL;DR
The X-ray diffraction results indicated that the β phase was predominant in all three compositions, and the increased tantalum content promotes the stability of this phase and reduces the α″ martensite contribution observed in alloys with lower tantalum content.
Abstract
New titanium alloys for biomedical applications are being developed to avoid the use of aluminum and vanadium, which may raise concerns regarding their long-term biological effects. In this study, the effect of tantalum content on the microstructure, hardness and electrochemical behavior of Ti–Mo–Zr–xTa alloys (x = 5, 10 and 15 wt.%) obtained by vacuum arc melting (VAR) was investigated. Characterization included assessment of samples via optical microscopy, scanning electron microscopy (SEM) with energy-dispersive spectroscopy (EDS) analysis and X-ray diffraction (XRD). Mechanical response and corrosion resistance were assessed using Vickers microhardness and electrochemical tests in Ringer’s solution, respectively. The X-ray diffraction results indicated that the β phase was predominant in all three compositions. Furthermore, the increased tantalum content promotes the stability of this phase and reduces the α″ martensite contribution observed in alloys with lower tantalum content. The mean microhardness decreased as the tantalum content increased, although measurements showed less dispersion with increasing indentation load. All alloys exhibited passive behavior in Ringer’s solution, with the Ti–15Mo–7Zr–15Ta alloy showing the lowest corrosion current density and corrosion rate.
Zirconium-based alloys are considered promising candidates for biomedical applications due to their favorable mechanical properties and corrosion resistance. In this study, Zr-10Nb-XMo alloys (X = 0; 2; and 4 wt.%) were fabricated using a combination of powder metallurgy and arc melting, followed by water quenching, in...
J. Zając, I. Matuła, M. Nabiałek et al.· Materials· 0 citations
β-Ti alloys are essential for biomedical applications due to their low elastic modulus, high strength, fatigue resistance, ductility, and corrosion resistance. β-metastable alloys such as Ti-12Mo-30Nb offer safer alternatives to Ti-6Al-4V by eliminating biotoxic elements (Al and V) linked to cell death and neurodegener...
C. Cossú, Mariana Soares Alvaro, João de Ataíde Garcia Precioso et al.· Materials Research· 0 citations
This study investigates the effect of cold working on the aging response and mechanical properties of an Al–4Cu–1.4Mg–0.6Ag (wt %) alloy. The alloy was produced from pure elemental constituents and processed by casting, homogenization, hot rolling, and solution heat treatment. Following solution treatment, approximatel...
Muhammad Farzik Ijaz, T. Alshammari, M. Soliman et al.· ACS Omega· 0 citations
Magnesium has been of interest to researchers as a potential biodegradable alternative to metal orthopedic implants due to its biocompatibility and mechanical properties that are similar to those of bone. However, magnesium implants corrode more quickly than would be beneficial. This study focused on the influence of c...
Francisco Miguel Sanchez-Sosa, Cristina Jiménez-Marcos, J. Mirza-Rosca et al.· Journal of Functional Biomat...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.