The AP-IJV max and the CSA-IJV max measurements showed excellent inter-observer reproducibility, suggesting the use of point-of-care ultrasound protocols for non-invasive volume assessment, particularly at the neck’s base or cricoid level.
Abstract
This study evaluates inter-observer variability in measuring internal jugular vein (IJV) ultrasonographic parameters using images obtained from medical ward patients. A cross-sectional study was conducted across 4 Italian hospitals. After brief training, 8 expert sonographers and 11 novices measured at the supraclavicular, cricoid, and submandibular levels, the anteroposterior expiratory maximum diameter (AP-IJV max), maximum cross-sectional area (CSA-IJV max), aspect ratio (AP-IJV max to latero-lateral diameter), and collapsibility index (IJV-c) on 60 IJV ultrasound images from 10 patients. Inter-observer reliability was assessed using the intraclass correlation coefficient. No significant differences were observed between experts and novices for AP-IJV max, CSA-IJV max, or aspect ratio across the different views. The lowest inter-examiner variability was found for AP-IJV max and CSA-IJV max at the supraclavicular level. Aspect ratio showed moderate reliability among experts but poor reproducibility among novices. The IJV-c demonstrated the highest inter-examiner variability in both groups. To our knowledge, this is the first multicenter study aimed at evaluating the method's reliability of different non-invasive acoustic measurements and windows to identify IJV dimensions better to use mainly in case of hypovolemia or fluid challenge. The AP-IJV max and the CSA-IJV max measurements showed excellent inter-observer reproducibility, suggesting the use of point-of-care ultrasound protocols for non-invasive volume assessment, particularly at the neck’s base or cricoid level.
Using panoramic ultrasonography to measure the pectoralis minor length, pectoralis minor thickness and pectoralis minor cross-sectional area may be considered a reliable method with excellent inter-day, intra- or inter-rater reliabilities.
R. Rijal, H. Chai, Jiu-Jenq Lin et al.· Journal of Functional Morpho...· 0 citations
Ultrasound-based measurement of preperitoneal fat thickness measurement using a convex probe is a highly reproducible and reliable technique across different observers and can be confidently implemented in routine clinical practice for the early identification of pregnant women at increased metabolic and obstetric risk...
R. Orozco, Juana Aranda, A. Navas et al.· Journal of Clinical Ultrasou...· 0 citations
Marked variability exists in IJV–CCA relationships, with the right side demonstrating more favourable anatomy for cannulation, according to the first bilateral, multi-level sonographic dataset from an African cohort.
Gouws L. Germishuys, B. Korda· Southern African Journal of...· 0 citations
Although lateral atlantodental distance measurements showed excellent inter-rater reliability, the SEM was relatively large compared with the small absolute values of the measurements, which limits the ability to detect subtle side-to-side asymmetries.
Jan Peter, Miklos Csato, Inga Paravicini et al.· Pediatric Radiology· 2 citations
Residents demonstrated markedly poorer inter-observer reliability compared to specialists, highlighting the impact of clinical experience on accurate end-vertebra selection and angle measurement.
A. Al Alawi, S. Al Kalbani, A. M. Al Barwani et al.· Acta orthopaedica Belgica· 0 citations
Assessment at the upper hyoid border provides the highest discrimination and may improve ultrasound-based airway risk stratification and may improve ultrasound-based airway risk stratification.
Çağdaş Savran, Özge Köner, Sibel Temür et al.· Indian Journal of Anaesthesi...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.