Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants

Sep 2026 · Bio-medical materials and engineering · Vol 37, pp. 285 - 302 · 0 citations · 22 references
Medicine

TL;DR

Among them, the TiCoCr coating demonstrated superior corrosion protection, indicating its strong potential for improving the long-term reliability and performance of biomedical implants.

Abstract

Background 316L stainless steel (SS) is widely used in biomedical implant applications because of its excellent mechanical properties, corrosion resistance, biocompatibility, and cost-effectiveness. However, its long-term performance in physiological environments is limited by localized corrosion, ion release, and inadequate surface interactions with biological tissues. Surface modification using Ti-based physical vapor deposition (PVD) coatings has emerged as a promising strategy to enhance the corrosion resistance and durability of implant materials. Objective This study aimed to investigate the effect of Ti-based PVD coatings, namely TiCoCr, TiN, and TiO2, on the corrosion behavior of 316L SS under simulated physiological conditions. Methods TiCoCr, TiN, and TiO2 coatings were deposited onto 316L SS substrates using the PVD technique. The corrosion performance of the coated and uncoated samples was evaluated in phosphate-buffered saline (PBS), Hanks’ solution, and Ringer's solution at 37 °C. Electrochemical corrosion parameters, including corrosion potential and corrosion current density, were analyzed to assess the effectiveness of the coatings. Results All Ti-based coatings improved the corrosion resistance of 316L SS compared with the uncoated substrate. Among the investigated coatings, the TiCoCr coating deposited for 90 min exhibited the best corrosion performance. In Ringer's solution, the coating showed a corrosion potential of −0.0504 V and a corrosion current density of 4.74 × 10−6 A/cm2. In Hanks’ solution, the same coating demonstrated a corrosion potential of −0.1815 V and a corrosion current density of 5.0537 × 10−6 A/cm2. The enhanced corrosion resistance was attributed to the protective and stable nature of the Ti-based coating layer. Conclusion The TiCoCr, TiN, and TiO2 PVD coatings significantly enhanced the corrosion resistance of 316L SS in simulated physiological environments. Among them, the TiCoCr coating demonstrated superior corrosion protection, indicating its strong potential for improving the long-term reliability and performance of biomedical implants.

View source

Similar papers

Open access Oct 2026

Multifunctional nanosilver-reinforced biocomposite coatings for metallic surface protection

Stainless steel 316L is widely used for biomedical implants because of its high mechanical strength, corrosion resistance, and durability; however, its relatively bioinert surface requires modification to improve biological interaction and osseointegration. In this study, multifunctional Ag/PMMA–NiO multilayer coatings...

Duaa S. Al-khafajy, Hanaa A. Al-kaisy, Mohanad N. al-Shroofy et al. · 0 citations
Open access Sep 2026

Improving Corrosion Protection for Biomedical SS316L Using SiN Thin Films Applied by RF Sputtering, Tested in Strong Oxidative Environment, Depending on RF Power

Biomedical-grade stainless steel (316L) is susceptible to corrosion in human body fluids, and the subsequent release of metallic ions may contribute to adverse health effects. Silicon nitride (SiN), a biocompatible material, offers strong adhesion and serves as an effective barrier on metallic substrates, significantly...

J. González-Parra, Ana A. Lara Vázquez, Cristian Z. Reyes Sanchez et al. · 0 citations
Open access Sep 2026

Corrosion Behavior of Ti-12Cr and Commercially Pure Titanium (CpTi) in AFNOR Artificial Saliva at 37°C

Metallic materials for orthodontic applications must exhibit good corrosion resistance, as they operate within the corrosive environment of the oral cavity. Titanium and its alloys are widely used as biomaterials owing to their favorable biocompatibility and corrosion resistance. This study aimed to evaluate the corros...

Aguswan Amirul Arif, Gunawarman Gunawarman, J. Affi · 0 citations
Open access 2027

Improvement of Electrochemical Behavior of Nitinol by Hydroxyapatite–Tantalum Oxide Coating Fabricated via Electrophoretic Deposition for Biomedical Applications

Introduction and Objectives: The widespread application of NiTi alloys in biomedical implants is constrained by the release of nickel ions, which may provoke allergic responses and carcinogenic risks. Employing biocompatible hydroxyapatite composite coatings offers a promising approach to suppress nickel ion leaching a...

Nazila Horandghadim, J. Khalil-Allafi · 0 citations
Open access Nov 2026

Comparative Study on Wear Behavior, Corrosion Resistance, and Bioactivity Performance of Conventional and nTopology-Designed DMLS Co-Cr Alloys for Biomedical Implant Applications

Objectives: To make a comparative study on the wear behavior, corrosion resistance, and bioactivity performance of conventional Co-Cr (Cobalt-Chromium) alloy and nTopology-designed Co-Cr alloy sintered by Direct Metal Laser for biomedical implant applications. Method: Comparative investigations were made on the CM-CoCr...

N. Rajitha, V. Srinivasan, G. Sathishkumar · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.