Aug 2026· Pediatric Radiology· 0 citations· 11 references
Medicine
TL;DR
The flexible blanket-like torso coil provided image quality similar to a conventional coil and was generally preferred by patients and MRI technologists.
Abstract
Background
Conventional phased-array torso coils used for abdominal MRI are relatively heavy and inflexible, potentially affecting patient comfort and technologist workflow.
Objective
To compare image quality, patient experience, and technologist experience using a recently United States Food and Drug Administration-cleared flexible, lightweight, blanket-like torso coil versus a conventional torso coil for pediatric abdominal MRI.
Materials And Methods
In this prospective institutional review board-approved study, 20 pediatric patients (7 years-old to 18 years-old) undergoing routine clinical outpatient abdominal MRI were imaged on the same 1.5-T system using both a conventional torso coil and a flexible blanket-like torso coil (Smart Fit TorsoCardiac; Philips Healthcare). After standard clinical imaging, selected sequences were repeated following coil exchange. Five pediatric radiologists independently evaluated paired image sets for subjective signal-to-noise ratio (SNR) and coil-related artifacts. Objective image quality was assessed using organ- and tissue-based SNR estimates and contrast-to-noise ratio (CNR) measurements. Patients and MRI technologists completed questionnaires regarding comfort, usability, and examination experience.
Results
All 20 patients (median age, 15 years; 55% female) underwent imaging with both coils. Radiologists rated the novel coil as similar to the conventional coil for subjective SNR across all three sequences under study; coil-related artifacts were uncommon (2% of assessments for all sequences evaluated). Objective analysis showed no significant image-based SNR differences for most sequences, although the flexible coil demonstrated higher liver SNR on axial diffusion-weighted imaging (adjusted P=0.01). CNR did not differ between coils. Patients reported greater comfort and less anxiety with the flexible coil; 55% preferred it for future MRI examinations versus 20% for the conventional coil. Technologists also favored the flexible coil, with 70% expressing an overall preference.
Conclusion
The flexible blanket-like torso coil provided image quality similar to a conventional coil and was generally preferred by patients and MRI technologists.
A high-density posterior cushion coil (HDPCC) can improve the SNR in pediatric MRI by conforming to the body and minimizing distance to the imaged volume when compared to a conventional rigid built-in table coil array. Posterior coil arrays built into MRI tables are mainstays but provide suboptimal performance in pedia...
T. Jao, Praveen Jayapal, Jana M. Vincent et al.· Bioengineering· 0 citations
Simultaneous structural-functional lung imaging in a single free-breathing acquisition was feasible in this cohort of older awake pediatric participants using 0.55-T MRI, with structural images suitable for evaluating major pulmonary findings and quantitative ventilation metrics correlating strongly with PREFUL.
Xin Miao, N. Lee, HaiThuy N. Nguyen et al.· Radiology advances· 0 citations
A fast, ungated 5D-MRI reconstruction method based on the CMR-MOTUS framework enables rapid, high-quality, and personalized motion characterization, demonstrating potential for integration into MRI-guided STAR treatments.
Maarten Terpstra, T. Olausson, M. Aubert et al.· 0 citations
This pilot study successfully translated a previously developed LF MRI canine cadaver brain protocol for in vivo application and compared the acquired images with paired 1.5 T MRI images from 21 different canine patients, representing the first in vivo usage and evaluation of a 0.05 T MRI in a clinical veterinary conte...
Elisabeth M. Burgers, Samantha Miles, Ruben van den Broek et al.· Veterinary Quarterly· 0 citations