Skip to content

Evaluation of Accuracy in Digital Impressions Using Compatible Scanbodies in Bone-Level Implants: An In Vitro Study

Aug 2026 · Journal of Oral Implantology · 0 citations

TL;DR

The type of scan body did not significantly affect the accuracy of digital impressions for bone-level implants and the mean and standard deviation of Root Mean Square Eror (RMSE) were calculated.

Abstract

Purpose: Digital impression techniques in dentistry have emerged as a precise alternative to conventional methods. The accuracy of this process depends on multiple factors, including the design and material of the scan body, the type of scanner used, and the implant conditions. Materials and Methods: Four types of scan bodies from Dentis, Dentium, Dio, and Novodent were evaluated across 40 samples (10 per group). A reference model was first obtained with an industrial scanner (T-SCAN Hawk 2), and the samples were then scanned with an itraoral scanner (Medit i700). The resualting STL files were aligned in 3-Matic, and geometric deviations from the reference model were measured using the Best-Fit Alignment algorithm. Data were analyzed in SPSS (version 27) using one-way ANOVA with Turkey’s post hoc test, with significance set at 0.05. Results: The mean and standard deviation of Root Mean Square Eror (RMSE) were calculated for four scan bodies: Dentis, Dentinum, Dio, and Novodent. The reference group, Dentis, had a mean RMSE of 0.21± 0.10. Dentium showed a similar RMSE (0.21±0.08), indicating comparable accuracy to Dentis (P˃0.05). In contrast, Dio and Novodent showed lower RMSE values (0.14±0.02 and 0.15±0.06, respectively), indicating higher accuracy, although the differences were not statistically were not statistically significant (P˃0.05). Conclusion: The type of scan body did not significantly affect the accuracy of digital impressions for bone-level implants (P˃0.05).

View source

Similar papers

Open access Aug 2026

IN VITRO EVALUATION OF ACCURACY OF DIGITAL IMPRESSIONS VERSUS CONVENTİONAL IMPRESSIONS AT VARYING IMPLANT DEPTHS FOR SINGLE CROWNS

Objective: This in vitro study aimed to evaluate the effect of implant vertical positioning on the accuracy of digital and conventional impressions for single implants using three-dimensional superimposition analysis.Material and Methods: A master model with a single implant analog (Biohorizons, 5.7 mm) was prepared at...

Vildan Aslıyüce, Nihal Özcan, Elif Yiğit İren et al. · 0 citations
Open access Aug 2026

In Vitro Analysis of the Effect of Intraoral Scan Body Design on the Accuracy of Complete Arch Implant Scanning

Evaluating how different ISB designs affect the trueness and precision of digital impressions in a completely edentulous maxillary arch with multiple implants found significant differences were found among ISBs in both trueness and precision.

Fernando Sanclemente-Reina, Carlos Serrano-Granger, Andrea Santamaría-Laorden et al. · 0 citations
Open access Jul 2026

Influence of Artificial Surface Markers on the Accuracy of Full-arch Digital Impressions in Edentulous Arches: An In Vitro Study

Full-arch intraoral scanning of edentulous models demonstrated clinically acceptable accuracy, within the limitations of this in vitro study, and should be interpreted cautiously when extrapolating to clinical intraoral conditions.

Emel Arslan, H. Yemenoğlu · 0 citations
Sep 2026

The accuracy of reverse scan body technique for capturing full-arch digital implant impressions: An in vitro study.

The RSB technique was inferior to the desktop scan in terms of digital impression and definitive prostheses accuracy, however, the RSB technique produced zirconia prostheses within the clinically acceptable deviation value of 0.15 mm.

Ahmed Elsayyad, C. Wyatt, Ross Bryant et al. · 0 citations
Aug 2026

Evaluation of four digital methods in capturing complete-arch implant positions: Direct scanning, splinted scan bodies, three-dimensional-printed scan aids, and intraoral photogrammetry.

Scan aids can enhance the performance of IOSs in acquiring complete-arch digital impressions, with trueness values approaching IPG systems, providing evidence for selecting optimal digital workflows in full-arch implant rehabilitation.

Lina Aljumaili, İ. Cinar · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.