A Novel Electromagnetic Coil (EMAG) Fenestrated Stent-Graft for Rapid Cannulation to Reduce Use of Contrast Agent and Radiation Exposure During Fenestrated EVAR.
Aug 2026· Journal of Endovascular Therapy· pp.
15266028261471720
· 0 citations· 23 references
Medicine
TL;DR
The findings of this study demonstrate the feasibility of the EMAG system as a novel approach for assisting branch-vessel cannulation during fenestrated endovascular aortic repair, offering a promising approach to improve patient safety in an increasingly common procedure.
Abstract
Endovascular aortic repair (EVAR) has emerged as a popular option for minimally invasive treatment of abdominal and thoracic aortic aneurysms, offering advantages over traditional open surgical methods by reducing immediate postoperative morbidity and mortality. Although the endovascular repair option is attractive, it can potentially increase patient risks associated with x-ray exposure during the procedure, as significant levels of ionizing radiation are generated during preoperative diagnostic angiography, perioperative device placement, and lifelong follow-up imaging. For treatment of complex aortic aneurysms involving visceral vessels, radiation exposure during fenestrated stent-graft repair is typically double that of conventional unfenestrated stent-graft delivery and placement, which puts patients and clinicians at risk of reaching lifetime radiation limits and potentially developing cancer. To address this issue, a novel electromagnetic (EMAG) system has been developed and studied to potentially reduce radiation overexposure during the procedures by expediting a key step of the process, namely cannulation of fenestrations. The solenoid electromagnetic EMAG system embedded surrounding the ostia of the fenestrations attracts the magnetized tip of either a guidewire or catheter into a side branch, rapidly and selectively cannulating branch vessels in the aorta. The EMAG prototype was designed and fabricated with selective design requirements. A comparative study between the EMAG system and a standard guidewire demonstrated that the average time to cannulate with the EMAG system was 5.73 ± 2.67 seconds, which was significantly less than the average time taken to cannulate with the standard guidewire (34.37 ± 39.91 seconds, P < .01). In addition, the feasibility of the EMAG device was evaluated by characterizing its attraction force, dislodging force, and temperature rise. This device has the potential to reduce radiation exposure during EVAR procedures, offering a promising approach to improve patient safety in an increasingly common procedure.Clinical ImpactThe findings of this study demonstrate the feasibility of the EMAG system as a novel approach for assisting branch-vessel cannulation during fenestrated endovascular aortic repair. By advancing this technology through further preclinical and clinical studies, the EMAG system has the potential to improve workflow, enhance procedural consistency, reduce fluoroscopy dependence, and contribute to safer and more efficient complex endovascular interventions.
In a patient with a symptomatic pararenal aneurysm undergoing urgent endovascular repair, electrified wire in situ fenestration (EWISF) proved challenging in a patient with a symptomatic pararenal aneurysm undergoing urgent endovascular repair.
S. Iodice, George Apostolidis, Daour Yousef al Sarhan et al.· Journal of Endovascular Ther...· 0 citations
F/B-EVAR guided by 3D simulation may allow for accurate planning of fenestration and branch positioning, potentially improving procedural success rate and suggesting a potential to enhance the quality of outcomes.
Yujing Zhang, Jing Wang, Cheng-Long Qu et al.· Therapeutic Advances in Card...· 0 citations
The case highlights both the utility and risks of advanced EVAR techniques in complex anatomy, and the wall-push technique, while useful for severe neck angulation, requires meticulous guidewire control and carries risk of vessel injury.
This approach avoids the high morbidity of emergency open bypass in high-risk patients and provide an effective endovascular bailout strategy to restore true lumen perfusion and avoid emergency surgical conversion in selected patients.
T. Vo, Cong Tien Nguyen, Thời Hải Nguyên Nguyễn· Tạp chí Phẫu thuật Tim mạch...· 0 citations
Type 2 endoleak (T2EL) is the most common complication after endovascular aneurysm repair (EVAR), occurring in 10%–25% of patients. Although many T2ELs follow a benign course, persistent T2EL is associated with sac expansion, secondary endoleaks, rupture, and aneurysm-related mortality. Endovascular treatment is indica...
J. Kwon· Korean Journal of Interventi...· 0 citations
This narrative review critically synthesizes current evidence regarding CTA, CEUS, and CT–ultrasound fusion imaging in post-EVAR surveillance, with particular emphasis on the incremental clinical value of fusion imaging beyond standalone CTA and CEUS.
M. Montatore, Gianmichele Muscatella, R. Tupputi et al.· Radiation· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.