Skip to content
Open access

Multi-GPU parallel framework for DOI-enabled long axial field-of-view PET image reconstruction

Sep 2026 · Physics in Medicine and Biology · Vol 71, pp. 205004 · 0 citations · 35 references
Physics Medicine

TL;DR

The proposed framework improves the scalability of DOI-enabled LAFOV-PET reconstruction by enabling its dominant computational components to efficiently utilize available GPU resources, establishing a foundation for high-performance reconstruction in next-generation PET systems.

Abstract

Objective. Depth-of-interaction (DOI)-enabled long axial field-of-view (LAFOV) positron emission tomography (PET) can mitigate parallax-induced resolution degradation, but DOI modeling substantially expands the lines-of-response space and increases computational cost. This study aimed to develop a scalable reconstruction framework for DOI-enabled LAFOV-PET. Approach. We present an optimized multi-GPU reconstruction framework based on list-mode ordered-subsets expectation maximization. The framework targets the major computational bottlenecks of DOI-enabled LAFOV-PET reconstruction, including sensitivity image calculation and Monte Carlo-based scatter estimation. Main results. The extended IQ phantom demonstrated near-linear scalability across multiple GPUs for sensitivity image calculation and Monte Carlo-based scatter estimation. Additional Derenzo and hybrid anthropomorphic phantom studies validated the imaging benefits of DOI modeling, including improved spatial resolution and performance under realistic imaging conditions. Significance. The proposed framework improves the scalability of DOI-enabled LAFOV-PET reconstruction by enabling its dominant computational components to efficiently utilize available GPU resources, establishing a foundation for high-performance reconstruction in next-generation PET systems.

Read PDF

Similar papers

Open access 2026

High-Performance GPU Implementation of Filtered Back Projection for Hemispherical Array Photoacoustic Tomography

Photoacoustic tomography is a promising biomedical imaging modality capable of providing high-resolution structural and functional information. However, large-scale three-dimensional (3D) image reconstruction using hemispherical detector geometries remains computationally demanding, limiting its applicability in real-t...

S. M. Ranjbaran, Ravi Prakash, Kai-Wei Chang et al. · 0 citations
Conference Open access Sep 2026

Study of attenuation correction in sparse-view tomographic dose reconstruction with a static multi-stack scintillating fiber detector

High-resolution two-dimensional dosimetry is important for radiotherapy quality assurance. Scintillating fiber tomodosimetry is attractive because of its near water equivalence and fine spatial sampling, but most implementations rely on detector rotation. Here, we report Monte Carlo simulations of a static multi-stack...

Sajjad Ahmad Khan, Luc Beaulieu, Louis Archambault · 0 citations
Aug 2026

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators

The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

F. Weng, Gao-Yu Chen, Yun-Long Zan et al. · 0 citations
Preprint Sep 2026

CTrex: A Research-Oriented Framework for Kernel- and Projection-Level Algorithm Development in CT Reconstruction

CTrex is introduced, a research-oriented, GPU-accelerated iterative reconstruction framework that exposes the projection-correction-backprojection pipeline down to the kernel level and allows non-ideal acquisition effects to be incorporated directly into the numerical operators rather than treated as external correctio...

Karel Desplenter, Wannes Goethals, T. de Schryver et al. · 0 citations
Open access Sep 2026

Beyond NEMA: robustness, DOI encoding, and multi-mouse imaging performance of the Bruker PET/CT Si78

Objective. This work presents a comprehensive evaluation of the Bruker PET/CT Si78 preclinical imaging system, combining standardized performance assessment, inter-system reproducibility analysis, and investigation of depth-of-interaction (DOI) encoding effects on image quality. Approach. Ten independently assembled sy...

L. Moliner, C. Correcher, A. Beltrá et al. · 0 citations
Preprint Oct 2026

Monte Carlo Framework for Physics-Based Design and Optimization of X-Ray Compressive Ghost Imaging Systems

X-ray ghost imaging has emerged as a promising computational imaging modality capable of forming images from spatially integrated measurements. Unlike optical implementations, image formation is governed by multiple energy-dependent photon-matter interactions: photoelectric absorption, Compton scattering, and fluoresce...

R. H. Shukrun, A. Ben Yehuda, Y. Korotinsky et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.