Nonlinear velocity dampers (NVDs) embedded in coupling beams may enhance the seismic performance of frame–core tube structures by dissipating energy and limiting structural damage. This study evaluates the seismic performance of a 20-story reinforced concrete (RC) frame–core tube building incorporating NVD-equipped coupling beams. Parametric studies are conducted at the frequent earthquake (FE) level, and nonlinear time-history analyses are performed at the design-basis earthquake (DBE) and rare earthquake (RE) levels. The results show that wall-pier flexure is the primary contributor to damper deformation, and mid-span placement is found to be relatively favorable. The optimal damping coefficient varies with the engineering demand parameters, whether base shear, drift, or additional damping, indicating that damping coefficient should be chosen based on a balanced consideration. For the N. Palm Springs ground-motion record considered in the damage assessment, the NVD-equipped models exhibit less flexural damage than the reference model for varying damping coefficients at both DBE and RE levels. These findings provide case-specific design guidance for applying NVD-equipped coupling beams in comparable RC frame–core tube buildings.
Earthquakes produce significant lateral forces on structures, which may lead to excessive displacement, structural
instability, and collapse if proper seismic resistant measures are not adopted. The present study focuses on the comparative
seismic performance evaluation of a G+11 reinforced cement concrete (RCC) buildi...
Utkarsh Mishra, R. Grover· International Journal for Re...· 0 citations
To improve the seismic performance and post-earthquake recoverability of low- and mid-rise steel frames, this study investigates the seismic performance and layout strategy of a self-centering friction damper (SCFD) through experimental and numerical studies. The SCFD combines the superelastic restoring capability of s...
Lu Wang, Zhao-Qun Chang, Yahui Zhang et al.· Buildings· 0 citations
Steel moment-resisting frames are widely used in seismic regions, but conventional beam–column connections often suffer from concentrated damage and difficult post-earthquake repair. To address these issues, this study proposes a novel replaceable energy-dissipating slit beam–column joint for steel frames. To enhance s...
This study investigates the seismic behaviour of a 10-storey shear-type building subjected to eleven near-field earthquake records while explicitly accounting for nonlinear soil-structure interaction (SSI). To improve seismic performance, a novel multiple active friction-tuned mass damper (MAFTMD) framework is proposed...
Morteza Akbari, M. Seifi, T. Falborski et al.· Archives of Civil and Mechan...· 0 citations
Control systems such as base isolators and dampers are widely used to reduce the seismic energy input to structures. Among passive control devices, Tuned Liquid Dampers (TLDs) mitigate structural vibrations through sloshing of the contained liquid, which generates counteracting inertial forces without requiring externa...
Birkan Dağ, Muzaffer Börekçi, M. Gençoğlu· Dicle Üniversitesi Mühendisl...· 0 citations
Designing high-rise reinforced concrete (RC) structures with adequate lateral stability is essential, especially in areas prone to earthquakes and strong winds. A G+9 RC framed structure was examined in this research with and without shear walls, utilizing STAAD as a tool for comparison.The PRO CONNECT Version. Model A...
A. Devi, B. S. Chandra· International Journal of AI...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.