Seismic performance enhancement of mid-rise buildings via multiple active friction-tuned mass dampers incorporating nonlinear soil-structure interaction

Jul 2026 · Archives of Civil and Mechanical Engineering · Vol 26 · 0 citations · 88 references

Abstract

This study investigates the seismic behaviour of a 10-storey shear-type building subjected to eleven near-field earthquake records while explicitly accounting for nonlinear soil-structure interaction (SSI). To improve seismic performance, a novel multiple active friction-tuned mass damper (MAFTMD) framework is proposed by integrating multiple friction-tuned mass dampers (MFTMDs) with an enhanced integral-derivative tilted (I-DT) control strategy. The nonlinear behaviour of the supporting soil is represented using the Hardin-Drnevich model, enabling strain-dependent stiffness degradation and damping effects to be captured under stiff, soft, and very soft soil conditions. The parameters of the MTMD and MFTMD configurations, along with the gains of the enhanced I-DT controller implemented in the MAFTMD system, are optimized using a multi-objective thermal exchange optimization (MOTEO) algorithm. The optimization simultaneously minimizes peak storey displacement and acceleration while satisfying inter-storey drift ratio constraints. The results demonstrate that incorporating friction mechanisms significantly enhances energy dissipation and structural response mitigation as compared to conventional MTMD systems. Furthermore, the proposed MAFTMD framework provides the most stable and effective overall performance under varying near-field earthquake characteristics and nonlinear soil conditions. The study also shows that nonlinear SSI strongly affects the performance and optimization of structural control systems. Overall, the proposed framework combines friction-based damping, active control, and nonlinear soil modelling to improve the seismic performance of mid-rise buildings under near-field earthquakes.

Read PDF

Similar papers

Open access Aug 2026

Seismic Control of Frame Structures Equipped with SMA-Based Self-Centering Friction Energy Dissipation Dampers

To improve the seismic performance and post-earthquake recoverability of low- and mid-rise steel frames, this study investigates the seismic performance and layout strategy of a self-centering friction damper (SCFD) through experimental and numerical studies. The SCFD combines the superelastic restoring capability of shape memory alloy (SMA) bars with the energy dissipation provided by non-asbestos organic (NAO) friction materials. Monotonic and cyclic tests were conducted to characterize the mechanical behavior of Ni–50.8 at. % Ti SMA bars and the hysteretic performance of the SCFD, based on which a numerical model of the damper was established and validated. An uncontrolled frame and four controlled frames employing diagonal, chevron, improved lower toggle-brace, and improved upper toggle-brace layouts were comparatively investigated to evaluate the effects of brace configuration, installation position, and damper quantity on seismic performance. The proposed damper exhibited an equivalent damping ratio ranging from 24% to 32%. When the SMA strain exceeded 6%, the residual deformation of the damper increased significantly, indicating that excessive SMA deformation should be avoided in practical design. Among the investigated configurations, the improved upper toggle-brace layout, combined with additional dampers installed at the first story, showed the best overall performance. Compared with the uncontrolled multi-story structure, the residual inter-story drift ratio was reduced by 76.7–93.5%, while the maximum acceleration reduction reached 28.9%. However, local acceleration amplification was observed in some cases because of the increased structural stiffness. These findings provide practical guidance for the layout design and engineering application of self-centering friction dampers in low- and mid-rise steel frames.

Lu Wang, Zhaoqun Chang, Yahui Zhang et al. · 0 citations
Open access Aug 2026

Seismic Performance of a Frame–Core Tube Building with Nonlinear Viscous Damper-Equipped Coupling Beams

Nonlinear velocity dampers (NVDs) embedded in coupling beams may enhance the seismic performance of frame–core tube structures by dissipating energy and limiting structural damage. This study evaluates the seismic performance of a 20-story reinforced concrete (RC) frame–core tube building incorporating NVD-equipped coupling beams. Parametric studies are conducted at the frequent earthquake (FE) level, and nonlinear time-history analyses are performed at the design-basis earthquake (DBE) and rare earthquake (RE) levels. The results show that wall-pier flexure is the primary contributor to damper deformation, and mid-span placement is found to be relatively favorable. The optimal damping coefficient varies with the engineering demand parameters, whether base shear, drift, or additional damping, indicating that damping coefficient should be chosen based on a balanced consideration. For the N. Palm Springs ground-motion record considered in the damage assessment, the NVD-equipped models exhibit less flexural damage than the reference model for varying damping coefficients at both DBE and RE levels. These findings provide case-specific design guidance for applying NVD-equipped coupling beams in comparable RC frame–core tube buildings.

Shen Liu, Bo Li, Hui Wang et al. · 0 citations
Open access Jul 2026

A ridge-isolated tuned mass damper for seismic rehabilitation of a 3D structure under bidirectional earthquakes.

Efficient and practical seismic control of structures-particularly through isolation systems-remains a significant challenge due to high implementation costs and construction complexity. Moreover, their application in retrofitting existing structures often requires extensive modifications.To address these challenges, this study proposes a novel and cost-effective seismic control system, termed the Ridge-Isolated Tuned Mass Damper (RITMD), which integrates the advantages of tuned mass damping and seismic isolation. A reduced-order two-degree-of-freedom (2DOF) model is developed to capture the coupled dynamic behavior of the primary structure and the RITMD system. An optimization framework based on the Particle Swarm Optimization (PSO) algorithm is employed to determine the optimal tuning parameters. Subsequently, closed-form design expressions are obtained using nonlinear regression analysis to facilitate practical engineering applications .The proposed approach is further extended to three-dimensional structural systems, and its performance is evaluated through nonlinear time-history analyses under bidirectional earthquake excitations. The results demonstrate that the RITMD system significantly reduces structural responses, including displacements, accelerations, inter-story drifts, torsional demands, and their corresponding root-mean-square (RMS) values.Overall, the proposed system provides an efficient, practical, and versatile solution for enhancing the seismic performance of both new and existing structures.

S. Etedali · 0 citations
Aug 2026

Seismic performance of base-isolated rigid-block systems enhanced by parallel tuned mass damper–inerter arrays

This study investigates the seismic performance of rigid-block-like structures equipped with a base isolation system enhanced by an array of parallel tuned mass damper–inerter devices (TMDIs). The protected structure, a typical data-center server rack, is modeled as a rigid cabinet that may experience uplift, rocking motion, and overturning under strong ground excitation. A comprehensive mechanical model is developed to describe the coupled rocking–translational dynamics of the cabinet, the isolation base, and the attached TMDI system, including impact and failure conditions. An extensive parametric investigation is carried out by varying the isolation period, the number and mass ratio of the TMDs, as well as the inertance associated with both the isolation base and the TMDs. The dynamic response is systematically evaluated through behavior maps, which identify full-contact, rocking, and overturning regimes in selected parameter planes. Numerical simulations are performed considering two cabinets with different slenderness and three historical earthquake records with distinct spectral characteristics. The results demonstrate that the proposed protection strategy is capable of significantly enlarging the safe response region, reducing both the minimum isolation period required to prevent uplift and the maximum displacement of the isolated base. Inerters attached to the TMDs are found to be particularly effective, while base-connected inerters provide additional benefits when combined with TMDIs. The effectiveness of the system is shown to depend on cabinet slenderness and seismic input characteristics. Overall, the study highlights the potential of parallel TMDI arrays as a robust and flexible solution for enhancing the seismic response of base-isolated rigid-block structures.

A. D. Di Egidio, Alessandro Contento, Manuel Ferretti · 0 citations
Open access Jul 2026

On the Seismic Response of Irregular Concrete Building with Shark Dampers Considering SSI Effects

This study investigates the three-dimensional seismic response of plan-irregular reinforced concrete (RC) frame structures subjected to near-fault pulse-like ground motions. The primary scientific contribution lies in evaluating how perimeter-distributed, short-stroke displacement-activated hysteretic dampers interact with complex structural torsional modes under the coupled influence of soil–structure interaction (SSI). Through unscaled nonlinear time–history analyses, this research exposes a critical vulnerability: foundation flexibility elongates the structural period, moving the system into close resonance with near-fault pulse content and more than doubling peak inter-storey drift demands. Concurrently, we demonstrate that the supplemental hysteretic system provides immediate elastic stiffness that successfully counteracts this SSI-induced period elongation, restricting peak drift amplifications to under 0.21% while actively mitigating torsional twisting. These findings provide a quantitative framework for the dual management of foundation flexibility and torsional irregularity using short-stroke metallic yielding devices.

Maria Eleni Diamantidou, P. Katsimpini, G. Papagiannopoulos et al. · 0 citations
Open access Jul 2026

Seismic Performance Evaluation of a Building Incorporating Different Lateral Load Resisting Systems

Earthquakes produce significant lateral forces on structures, which may lead to excessive displacement, structural instability, and collapse if proper seismic resistant measures are not adopted. The present study focuses on the comparative seismic performance evaluation of a G+11 reinforced cement concrete (RCC) building incorporated with different vibration control system using ETABS 20. The building was analyzed for Seismic Zone V using the Response Spectrum Analysis (RSA) method in accordance with the provisions of IS 1893 (Part 1): 2016. Six structural models were considered in the study, namely bare frame structure, fluid viscous damper model, friction damper model, X-bracing model, shear wall model, and lead rubber bearing (LRB) base isolated model. The seismic performance of each model was evaluated based on parameters such as maximum storey displacement, storey drift and storey shear. The results obtained from the analysis indicate that the Shear Wall model provides the most effective reduction in displacement and drift due to its Enhanced stiffness, although the shear wall and bracing systems significantly improve structural stiffness but attract higher seismic forces hence greater base shear than bare frame model. The fluid viscous damper and friction damper showed overall good seismic performance by reducing the overall displacement, drift and storey shear without attracting higher seismic forces. The base isolated model increases the displacement due to increased flexibility in the structure but reduces drift and force transmission into the structure. The study concludes that vibration control systems considerably enhance the seismic performance of RCC structures and assist in improving structural safety in earthquake-prone regions.

Utkarsh Mishra, Rakesh Grover · 0 citations