This paper develops a capacitor-voltage ripple-control scheme that combines negative-sequence second-harmonic capacitor-voltage feedback with third-harmonic zero-sequence voltage injection. An arm-energy model incorporates the common dc current, auxiliary-MMC voltage allocation, and ac support duty. The dc-series connection of a diode rectifier unit (DRU) and a reduced-rating modular multilevel converter (MMC) reduces the voltage rating of the offshore auxiliary converter, while submodule capacitance remains constrained by internal energy fluctuations. The rated-point comparison at 9000 μF gives maximum single-sided ripple indices of 7.21%, 5.51%, and 3.53% for conventional circulating-current suppression, additional third-harmonic injection, and the combined strategy, respectively. In the corresponding capacitance comparison, the combined-strategy case uses 4460 μF, equivalent to a 50.44% reduction in capacitance and nominal stored energy relative to the 9000 μF baseline. Waveform-based estimates reveal a trade-off: third-harmonic injection alone gives the lowest arm-current root mean square (RMS) value, whereas the combined strategy gives the lowest ripple and the largest negative current extreme. The two configurations recover dc voltage and transferred power following the investigated balanced fault, with larger capacitor-voltage excursions in the reduced-capacitance combined case. These results demonstrate rated-point capacitance reduction potential and identify the current and transient-voltage constraints that must be considered in practical sizing.
This paper presents a self-balanced five-level active neutral-point-clamped inverter with unity voltage gain. The proposed topology consists of seven active switches, six diodes, a low-voltage switched capacitor, and two dc-link capacitors to generate a five-level output voltage without requiring an additional voltage-...
Rezwan Allabasha, K. Vijayakumar, Meshari S. Alshammari et al.· IEEE Access· 0 citations
In this study, a high-frequency common-mode injection approach aimed at reducing capacitor-voltage ripple in a modular multilevel converter (MMC) is considered, and the injection-voltage expression commonly used in the literature is extended to include a phase term. Accordingly, a phase-adjusted injection model is defi...
With the increasing penetration of distributed generation, electric vehicles and single-phase loads in the low-voltage distribution network, flexible interconnected systems face more prominent three-phase unbalance and direct-current (DC)-side voltage regulation problems. Unbalanced loads not only lead to asymmetry of...
Yangxin Qiu, Min Yang, Jing-Hang Li et al.· Energies· 0 citations
INTRODUCTION: This paper investigates a fault ride-through control strategy for modular multilevel converter (MMC) based converter valves under low-voltage ride-through (LVRT) requirements in large-scale wind power transmission.OBJECTIVES: To develop an enhanced LVRT control integrating hierarchical voltage balancing,...
This article proposes a robust control strategy to minimize grid current harmonics in three-phase diode rectifier-fed permanent magnet synchronous motor (PMSM) drives featuring a small DC-link capacitance. First, a virtual impedance-based active damping scheme is introduced to emulate a series R-C damper. This suppress...
The deployment of next-generation ultra-high-power tandem photovoltaic (PV) modules demands front-end DC-DC converters capable of processing high input currents while achieving large DC voltage gain. However, conventional high-gain topologies are often constrained by excessive component stresses, elevated device counts...
M. E. El Kattel, Robson Mayer, Kassio Derek Nogueira Cavalcante et al.· IEEE Access· 0 citations