Skip to content
Conference Open access

The Phase Angle of Injected Circulating Current and Common-Mode Voltage Components and Its Impact on Submodule Capacitor Voltage in the Modular Multilevel Converter

Sep 2026 · 2026 IEEE 22nd International Power Electronics and Motion Control Conference (PEMC) · pp. 1-6 · 0 citations · 16 references

Abstract

In this study, a high-frequency common-mode injection approach aimed at reducing capacitor-voltage ripple in a modular multilevel converter (MMC) is considered, and the injection-voltage expression commonly used in the literature is extended to include a phase term. Accordingly, a phase-adjusted injection model is defined by introducing the phase angle $\theta_{z}$ into the injection voltage $u_{z}$, and the time-domain effects of this parameter on the capacitor-voltage ripple and the high-frequency circulating-current component are investigated. The simulation results indicate that $\theta_{z}$ is not limited to introducing a horizontal phase shift in the waveform; rather, it provides a performancecritical degree of freedom that significantly influences the ripple amplitude and the associated circulating-current magnitude. Moreover, the $\theta_{z}$ sensitivity analysis shows that the ripple does not follow a consistent trend with respect to the phase angle and can increase sharply within a specific phase region. Finally, the relationship between the peak-to-peak capacitor-voltage ripple and the root-mean-square value of the circulating current suggests that the choice of $\theta_{z}$ governs the balance between ripple reduction and circulating-current stress. Additional simulations conducted under different modulation indices, fundamental frequencies, and load conditions also demonstrate that the influence of $\theta_{z}$ is not limited to the baseline operating point.

Read PDF

Similar papers

Open access Sep 2026

Capacitor-Voltage Ripple Control and Capacitance Reduction Potential of the Auxiliary MMC in a Series-Connected DRU–MMC Offshore HVDC System

This paper develops a capacitor-voltage ripple-control scheme that combines negative-sequence second-harmonic capacitor-voltage feedback with third-harmonic zero-sequence voltage injection. An arm-energy model incorporates the common dc current, auxiliary-MMC voltage allocation, and ac support duty. The dc-series conne...

Long Zhao, Li-Na Zhang, Zhen-Hua Yuan et al. · 0 citations
Open access 2026

Single-Phase Asymmetric Harmonic Current Injection for Zero-Current Interruption of Bypass Switch During MMC-UHVDC Valve Group Energization

To address the challenge of zero-current interruption of a bypass switch (BPS) during valve group energization in modular multilevel converter (MMC)-based ultra-high-voltage direct current (UHVDC) systems, this paper proposes a novel single-phase asymmetric harmonic injection control strategy. The injection of harmonic...

Jie-Feng Wang, Jun-Hui Ren, Hao Wang et al. · 0 citations
Aug 2026

Analytical Common-Mode Modeling of a Five-Level Active-Neutral-Point-Clamped Converter

In this paper, an equivalent frequency-domain common-mode (CM) model is presented for a five-level active-neutral-point-clamped (ANPC) inverter and validated against the full time domain model. The equivalent model highlights additional High Frequency (HF) sources that are not apparent in the time-domain CM voltage mea...

Georgios Erotas, Patrick Koch, N. Moonen et al. · 0 citations
Open access 2026

ANALYSIS OF THD, RMS OUTPUT VOLTAGE AND VOLTAGE STREE ACROSS SWITCHING DEVICE FOR 1500V DC BUS THREE LEVEL ANPC INVERTER

Multilevel topologies have been used more frequently for high voltage applications in order to produce a staircase voltage waveform with total harmonic distortion (THD). This has increased interest in high-power systems and prompted the continuous development of advanced topologies. This paper discusses the advantages...

Miteshkumar N. Priyadarshi, Sandeep Chakravorty · 0 citations
Conference Sep 2026

Closed-Form Modelling of Peak Circulating Current in Parallel-Interleaved Two- and Three-Level VSIs

Parallel interleaved voltage-source inverters (VSIs) are widely employed in high-power applications to improve power capability, efficiency, and output current quality. However, interleaving also introduces high-frequency circulating currents between parallel inverter legs, which increase losses and constrain the desig...

M. Naveed, T. Hoeksma, T. Soeiro · 0 citations