It is asked whether judges detect omissions in clinical notes, and two methods reach it independently and trade off: a per-fact pipeline, and a GEPA-evolved prompt doing the same in one call.
Abstract
Ambient AI scribes draft clinical notes, and published audits find their dominant error is omission: information the encounter established that the note fails to record. The standard check is an LLM judge: a second model reads the note against the transcript and flags problems. We ask whether judges detect omissions. Public corpora cannot supply the answer key: their clinician reference notes and transcripts are materially discrepant. Our benchmark has 500 single-error note pairs from audited fact sheets, 298 with a named fact certainly absent and 202 added-or-altered controls. Across eight judge designs, paired discrimination (the flawed note below its clean twin, 0.5 a coin flip) reads 0.79-0.94 on added or altered content and 0.50-0.63 on omissions. On single notes, no design flags omissions reliably more often than perfect notes. Wording changes, voting and GEPA prompt optimisation move the operating point without creating usable detection. Restructuring the task recovers it: list the facts the transcript establishes, then check the note for each. Two methods reach it independently and trade off: a per-fact pipeline, and a GEPA-evolved prompt doing the same in one call. The pipeline's flags name the missing fact and its severity at 2.7% false alarms. The single call detects more (36.9% against 24.6%, p=0.002) at 6.2% false alarms and a tenth of the cost per note. A physician author validated 70 items and, where the two routes disagree, sided with the pipeline on 10 of 10 (p=0.002). A second clinician, not an author, graded the severity rubric blind and agrees to within a grade. On real vendor notes from a companion census no benchmark threshold transfers, but the re-calibrated single call detects more than the best of the eight at half its false-alarm rate. Omissions whose fact is restated elsewhere defeat both routes. We release the benchmark, prompts and judgements.
The judges behave as a consistent, near-non-differential, clinician-equivalent instrument, which licenses a directional AI-versus-clinician contrast under a non-differential misclassification argument, subject to its conditions.
H. Bergman, V. Liu, B. Austin et al.· medRxiv· 1 citation· ⚡1
Audited three commercial AI scribes on the same 142 consultations: 565 notes from recorded UK primary-care and US ambulatory encounters plus authored scenarios, with one failure mode drawn from published scribe-error taxonomies.
Sebastian Fox, L. Markham, Ryan Lail et al.· 1 citation· ⚡1
In this simulation, AI-generated notes scored higher on documentation quality, varied less, and carried fewer clinically significant errors than notes written on the same consultations by junior-to-middle-grade clinicians.
H. Bergman, V. Liu, B. Austin et al.· medRxiv· 1 citation
It is suggested that trustworthy clinical decision support should be evaluated by both average correctness and stability across medically equivalent patient narratives.
This work model the systematic component as coding style $\psi$, a coder- or site-specific policy over what to code and how much to document, and recast coding as $p(\mathrm{code}\mid\mathrm{note},\psi)$, estimating $\psi$ with a 10-dimension rubric.
Han-Chin Shing, Jack Moriarty, Ryan Ware et al.· 0 citations
Findings and error-scope analyses show that benchmark agreement reflects report size and error definitions as well as medical error detection, and local RadMatch achieves stronger agreement on clinically significant errors in both expert datasets and on total errors in the shared RadEvalExpert subset.