Coupled Nonlinear Torsional Seismic Behaviour of a Triple-Friction-Pendulum-Isolated Five-Storey RCC Building Under Nonstationary Earthquake Excitation
Triple Friction Pendulum (TFP) bearings are widely employed as seismic isolation systems to reduce seismic force and deformation demands in structures. However, the combined influence of vertical mass-distribution irregularity, soil–structure interaction (SSI), structural eccentricity, and nonstationary earthquake excitation on the nonlinear torsional response of TFP-isolated buildings remains insufficiently understood. This study investigates the seismic response of a five-storey reinforced concrete (RCC) building equipped with TFP bearings subjected to nonstationary spectrum-compatible horizontal earthquake ground motions. The investigated structure represents a low-to-medium-rise isolated building with a superstructure period Ts ≤ 0.5 s, and the conclusions are applicable within the examined structural configuration, adopted TFP properties, and equivalent SSI modelling assumptions. A nonlinear time-history analysis framework combined with Monte Carlo-based spectrum-compatible ground-motion simulations is employed to evaluate the effects of SSI, structural eccentricity, and vertical mass-distribution irregularity. Validation against OpenSees benchmark simulations demonstrates strong agreement in the predicted structural responses. Parametric analyses show that increasing the soil stiffness ratio from 0.5 to 2.0 reduces the normalized isolation displacement by approximately 46.5% and the corner rotational response by approximately 36.7%. Conversely, increasing the vertical mass-irregularity ratio from 1.0 to 1.5 increases the inter-storey drift ratio by approximately 60% and corner-displacement magnification by approximately 48.6% within the investigated cases. The results demonstrate that seismic response is governed not only by the magnitude of vertical mass irregularity but also by its location due to changes in inertia-force distribution, modal participation, and lateral–torsional coupling. These findings highlight the importance of considering SSI and vertical mass distribution simultaneously when assessing the seismic performance of torsionally asymmetric TFP-isolated RCC buildings. Further studies incorporating taller structures, multidirectional excitation, detailed soil–foundation interaction models, and experimentally calibrated TFP properties are required to extend the applicability of the findings.
Buckling-restrained braces (BRBs) and viscous fluid dampers (FVDs) dissipate seismic energy through yielding hysteresis and velocity-dependent action, respectively. This paper takes a six-story reinforced concrete (RC) frame as the object, compares the seismic mitigation performance of the two types of devices under a...
Zheng-Wen Gong, Peng-Fei Ma· Journal of Composites Scienc...· 0 citations
This study examines how lead-rubber bearing (LRB) isolation changes the seismic response of a ten-story reinforced-concrete building using matched fixed-base and isolated models. Three-dimensional ETABS models were analyzed using nonlinear direct integration under the EQ-X component of the 1999 Kocaeli earthquake recor...
A. Kadhum, Mohammed Abid Jameel, Mohammed A. Radi et al.· Civil Engineering Journal· 0 citations
This paper investigates the seismic response and stress-strain state of a two-span reinforced concrete highway bridge subjected to real earthquake records using advanced numerical modeling. A three-dimensional model of a 48 m long bridge was developed considering structural characteristics, support conditions, and soil...
D. Bekmirzaev, M. Berdibaev, Р. Аъзамов· E3S Web of Conferences· 0 citations
This study investigates the seismic performance of rigid-block-like structures equipped with a base isolation system enhanced by an array of parallel tuned mass damper–inerter devices (TMDIs). The protected structure, a typical data-center server rack, is modeled as a rigid cabinet that may experience uplift, rocking m...
A. Di Egidio, A. Contento, Manuel Ferretti· Journal of Vibration and Con...· 0 citations
This study evaluates the post-earthquake damage of a 17-story plan-irregular reinforced concrete (RC) building damaged during the 2024 Hualien earthquake. A three-dimensional numerical model was constructed in ETABS, utilizing nonlinear component characteristics derived from the mechanics-based Seismic Evaluation of RC...
Closely spaced adjacent structures are vulnerable to dynamic interaction during earthquakes, which may amplify structural responses and increase seismic damage. Although various passive control devices have been proposed for adjacent structures, nonlinear friction-based control under simultaneous bidirectional horizont...
K. Kiran, D. Naveenkumar· Journal of Earthquake and Ts...· 0 citations