Aug 2026· Journal of Vibration and Control· 0 citations· 38 references
Abstract
This study investigates the seismic performance of rigid-block-like structures equipped with a base isolation system enhanced by an array of parallel tuned mass damper–inerter devices (TMDIs). The protected structure, a typical data-center server rack, is modeled as a rigid cabinet that may experience uplift, rocking motion, and overturning under strong ground excitation. A comprehensive mechanical model is developed to describe the coupled rocking–translational dynamics of the cabinet, the isolation base, and the attached TMDI system, including impact and failure conditions. An extensive parametric investigation is carried out by varying the isolation period, the number and mass ratio of the TMDs, as well as the inertance associated with both the isolation base and the TMDs. The dynamic response is systematically evaluated through behavior maps, which identify full-contact, rocking, and overturning regimes in selected parameter planes. Numerical simulations are performed considering two cabinets with different slenderness and three historical earthquake records with distinct spectral characteristics. The results demonstrate that the proposed protection strategy is capable of significantly enlarging the safe response region, reducing both the minimum isolation period required to prevent uplift and the maximum displacement of the isolated base. Inerters attached to the TMDs are found to be particularly effective, while base-connected inerters provide additional benefits when combined with TMDIs. The effectiveness of the system is shown to depend on cabinet slenderness and seismic input characteristics. Overall, the study highlights the potential of parallel TMDI arrays as a robust and flexible solution for enhancing the seismic response of base-isolated rigid-block structures.
This study investigates the seismic behaviour of a 10-storey shear-type building subjected to eleven near-field earthquake records while explicitly accounting for nonlinear soil-structure interaction (SSI). To improve seismic performance, a novel multiple active friction-tuned mass damper (MAFTMD) framework is proposed...
Morteza Akbari, M. Seifi, T. Falborski et al.· Archives of Civil and Mechan...· 0 citations
To improve the seismic performance and post-earthquake recoverability of low- and mid-rise steel frames, this study investigates the seismic performance and layout strategy of a self-centering friction damper (SCFD) through experimental and numerical studies. The SCFD combines the superelastic restoring capability of s...
Lu Wang, Zhao-Qun Chang, Yahui Zhang et al.· Buildings· 0 citations
Nonlinear velocity dampers (NVDs) embedded in coupling beams may enhance the seismic performance of frame–core tube structures by dissipating energy and limiting structural damage. This study evaluates the seismic performance of a 20-story reinforced concrete (RC) frame–core tube building incorporating NVD-equipped cou...
Shen Liu, Bo Li, Hui Wang et al.· Buildings· 0 citations
Efficient and practical seismic control of structures-particularly through isolation systems-remains a significant challenge due to high implementation costs and construction complexity. Moreover, their application in retrofitting existing structures often requires extensive modifications.To address these challenges, t...
This paper investigates the seismic performance of a nonlinear passive control device, namely a Bi-Stable Mass Damper–Inerter (BSMDI), designed to mitigate structural displacements. The system combines a mass damper connected to the primary structure through a bistable (snap-through) nonlinear element with a grounded i...
Remo Pacella, S. Di Nino, A. Di Egidio· Applied Sciences· 0 citations
Control systems such as base isolators and dampers are widely used to reduce the seismic energy input to structures. Among passive control devices, Tuned Liquid Dampers (TLDs) mitigate structural vibrations through sloshing of the contained liquid, which generates counteracting inertial forces without requiring externa...
Birkan Dağ, Muzaffer Börekçi, M. Gençoğlu· Dicle Üniversitesi Mühendisl...· 0 citations