Oct 2026· Periodica polytechnica. Civil engineering· Vol 70, pp. 1074-1087· 0 citations· 31 references
Abstract
The Plate-Shell Integrated Concrete Liquid-Storage Structure (PSICLSS) is an emerging form of water treatment infrastructure. To elucidate its dynamic response mechanism and evaluate the seismic mitigation performance of an SMA-reinforced hybrid isolation system, this study employed finite element analysis (FEA) and shaking table testing to investigate the structural dynamic response characteristics and liquid sloshing behavior under seismic excitation. Shaking table tests were conducted under both unidirectional and bidirectional seismic excitations to further characterize the dynamic responses of the PSICLSS. The results demonstrate that the beams of the PSICLSS are susceptible to tensile failure under seismic loading, whereas the bottom supporting columns and lower slab are vulnerable to shear failure. The structural acceleration response exhibits an increasing amplification effect with increasing plate elevation, and the hydrodynamic pressure of the internal liquid is consistently greater than that of the external liquid. The proposed SMA-reinforced hybrid isolation layer demonstrates effective seismic mitigation performance by reducing the acceleration response of the PSICLSS and lowering the peak hydrodynamic pressure; however, it also results in increased liquid sloshing height. When vertical seismic excitation is considered, the hydrodynamic pressure increases significantly, while the residual displacement of the isolation layer decreases correspondingly.
Beam–column joints (BCJs) are widely recognized as critical structural components that govern the seismic performance of reinforced concrete (RC) frame structures. Their measurements captured changes associated with susceptibility to brittle joint shear failure under cyclic loading, which often results in rapid strengt...
George M. Sapidis, N. Papadopoulos, M. Naoum et al.· Applied Sciences· 0 citations
Connections play a critical role in governing the robustness of steel structures under extreme loading conditions. This study proposes three novel beam–column connection prototypes incorporating semi-elliptical ductile components to enhance structural performance under multi-hazard scenarios. Finite element models...
Yan Su, Yu Liu, Bo-Han Sun et al.· Lifeline Emergency and Safet...· 0 citations
The increasing environmental impact of conventional concrete production and the seismic vulnerability of reinforced concrete structures in Morocco have encouraged the development of sustainable alternative construction materials. This study evaluates the seismic and thermal performance of reinforced concrete frames...
A. Souileh, Latifa Ouadif, Rabab Zouai et al.· Open Civil Engineering Journ...· 0 citations
This paper presents a novel prefabricated reinforced concrete (RC) beam‐column joint featuring a hybrid connection system that integrates friction side plates (FSPs) and composite energy‐dissipation boxes (EDBs). The proposed joint is specifically engineered to achieve controllable plasticity and superior rotational...
Tao Wang, Ming-Sheng He, Zhi-Qiang Dong et al.· Structural Concrete· 0 citations
Structural irregularities can significantly alter the seismic response of reinforced concrete buildings by modifying stiffness, mass distribution and load paths. This study evaluates the influence of structural irregularities and shear wall placement on the seismic performance of mid-rise reinforced concrete buildings...
S. Nirushan, H. Damruwan, C. Lewangamage· Proceedings of the Civil Eng...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.