Seismic Response Control and Performance Assessment of a Base-Isolated Soft-Storey Reinforced Concrete Structure with the Integration of a Negative Stiffness Device and Supplemental Fluid Viscous Damper
Passive energy dissipation systems are among the effective retrofit strategies for improving the seismic performance of existing reinforced-concrete (RC) structures by limiting earthquake-induced demands and structural damage. This study aims to compare the seismic performance of friction dampers (FDs) and fluid viscou...
Muhammed Ulucan, Taha Yasin Altıok, Musa Yetkin et al.· Buildings· 0 citations
This study quantifies the seismic response of a ten-story reinforced concrete smart structure with base isolation and supplemental fluid viscous dampers. A 3D SAP2000 model was created for a reinforced concrete moment-frame building with a central shear wall, 10 stories, a total height of 36.0 m, and plan dimensions of...
Adil Khan, H. Hussein· European Journal of Engineer...· 0 citations
Buckling-restrained braces (BRBs) and viscous fluid dampers (FVDs) dissipate seismic energy through yielding hysteresis and velocity-dependent action, respectively. This paper takes a six-story reinforced concrete (RC) frame as the object, compares the seismic mitigation performance of the two types of devices under a...
Zheng-Wen Gong, Peng-Fei Ma· Journal of Composites Scienc...· 0 citations
The seismic resistance of data center is crucial due to its contribution to the ability to maintain business continuity when faced with a high seismic force. In this subject, the current paper aims at performing a comparative analysis of the structural behavior of conventional dual system and modified system equipped w...
Dimas Prasasti Renandhito, J. I. Rastandi, J. Sjah· Jurnal PenSil· 0 citations
Triple Friction Pendulum (TFP) bearings are widely employed as seismic isolation systems to reduce seismic force and deformation demands in structures. However, the combined influence of vertical mass-distribution irregularity, soil–structure interaction (SSI), structural eccentricity, and nonstationary earthquake exci...
This paper investigates the seismic control of a 40-story high-rise building equipped with a Tuned Mass Damper (TMD) and an Active Tuned Mass Damper (ATMD) while considering Soil–Structure Interaction (SSI) effects. The structure is evaluated under four foundation conditions, including fixed-base, soft-soil, medium-soi...
Motasam Mousaviyan Safakhaneh, M. Fahimi-Farzam, H. Ahmadi et al.· Scientific Reports· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.