Skip to content

Comparative Analysis of Effective Doses of Medical Exposure in Children on PET/CT with Digital and Analog Detectors

Sep 2026 · Meditsinskaya Fizika · pp. 94-108 · 0 citations · 20 references

TL;DR

The use of PET/CT systems equipped with digital detectors is associated with a reduction in radiation exposure in pediatric patients and further dose optimization should focus primarily on the CT component, particularly the use of additional contrast-enhanced CT acquisitions.

Abstract

Purpose: To assess the effective dose (ED) associated with 18F-FDG PET/CT in pediatric patients undergoing examinations on PET/CT scanners equipped with digital detectors, to quantify the contributions of the PET and CT components to the total dose, and to compare the findings with data obtained from previous-generation PET/CT systems. Materials and Methods: This single-center retrospective study included 1,899 pediatric patients who underwent 2,793 PET/CT examinations in 2024–2025 on two Discovery MI scanners (General Electric Healthcare, USA) with a 20-cm axial field of view. Patients were stratified into four age groups: 0–2, 3–7, 8–12, and 13–17 years. The ED attributable to the PET component was estimated from the administered 18F-FDG activity using age-specific dose coefficients in accordance with MU 2.6.1.3700-21, while the ED from the CT component was calculated from the dose-length product (DLP) using the corresponding age-specific conversion coefficients specified in MU 2.6.1.3584-19. Results:The mean total ED was 21.7 mSv (range, 7.1–82.8 mSv). With increasing age, the relative contribution of the CT component increased from 49.2% to 76.9%, whereas the contribution of the PET component decreased from 50.7 % to 23.0%. The strongest effect on total ED was associated with additional contrast-enhanced CT acquisitions, which increased total ED by 34–65%. Neither patient arm position nor scan length showed a consistent association with ED. Compared with previous-generation PET/CT systems, total ED was reduced by 4.7–10.1% across the age groups, primarily due to a 17–21% reduction in the PET component. Conclusion: The use of PET/CT systems equipped with digital detectors is associated with a reduction in radiation exposure in pediatric patients. Further dose optimization should focus primarily on the CT component, particularly the use of additional contrast-enhanced CT acquisitions.

View source

Similar papers

Open access Sep 2026

Size-Specific Dose Estimate Assessment in Adult Non-Contrast Computed Tomography Abdomen: A Cross-Sectional Dose Evaluation Study

Objectives To evaluate and compare conventional radiation dose metrics (computed tomography dose index volume [CTDIvol] and dose length product [DLP]) with size-specific dose estimates (SSDEs) in adult patients undergoing non-contrast computed tomography (NCCT) abdomen examinations. Materials and Methods This study aim...

S. Verma, Rohit Sharma, A. Mishra et al. · 0 citations
Review Sep 2026

Assessment of CT doses and practices based on large data collected over four years in six hospitals of regional health network.

INTRODUCTION Computed tomography (CT) contributes substantially to medical radiation exposure, and considerable dose variation has been reported across scanners and facilities. This study evaluated CT radiation doses and practices across eight CT scanners in six facilities within a regional healthcare network in Canada...

M. Nassiri, N. Moghadam, Ariane-Sophie Painchaud-Bouchard et al. · 1 citation
Open access Sep 2026

Quantitative accuracy and clinical utility of ultra-low dose CT protocols for attenuation correction in PET/CT

In PET/CT imaging, CT frequently accounts for more than 50% of the total radiation exposure, even when used solely for attenuation correction and anatomical localisation. This poses a major limitation for dose-sensitive populations, including pregnant women and paediatric patients. This study systematically evalu...

Georgios I. Angelis, Y. Gholami, K. Willowson et al. · 0 citations
Oct 2026

Estimation of Effective Dose Received by Caregivers During [18F]FDG PET/CT Studies.

Caregiver radiation exposure during patient [18F]FDG PET/CT was low and remained within acceptable limits but varied considerably with caregiver-patient proximity and the time spent with the patient.

Darivemula Graham Stains, Prabu Titus Devakumar, Justin Benjamin et al. · 0 citations
Open access Oct 2026

Correlation of size specific dose estimates with organ dose in abdominal spectral computed tomography

Abstract Background In abdominal spectral Computed Tomography (CT), organ dose assessment is important for radiation safety but remains challenging due to the complexity of Monte Carlo (MC) simulations. Purpose This study aimed to compare the correlations of three size‐specific dose estimate (SSDE) metrics (including t...

Tian Qin, Qing-Ting Sun, Yi-Han Fan et al. · 0 citations
Oct 2026

Radiation Dose Assessment in Routine Adult Computed Tomography Examinations: A Multi-center Retrospective Study.

BACKGROUND Computed tomography (CT) plays an essential role in diagnosing and imaging various body structures, but it continues to be one of the most frequent sources of medical radiation exposure. Diagnostic reference levels (DRLs) represent critical values for radiation dose monitoring and dose optimization. OBJECT...

N. Alomairy, Nouf Tawashi, Reema Daghriri et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.