Skip to content

Fair Compression Benchmarking, Calibration-Aware Uncertainty Quantification, and Radiologist-Validated Explainability for Trustworthy Edge-Deployed COVID-19 Chest X-Ray Screening

Aug 2026 · Natural Resources for Human Health · 0 citations · 52 references

Abstract

Background: COVID-19 diagnostic capacity remains limited in low- and middle-income countries (LMICs). Prior edge-AI benchmarking studies for COVID-19 chest X-ray (CXR) classification often compress proposed models more aggressively than baselines, introducing a systematic optimism bias. Methods: We apply an identical three-stage Edge-Aware Optimisation Pipeline (dynamic-range quantisation, INT8 quantisation-aware training, structured L1-norm pruning) to seven architectures, including a proposed 1.91M-parameter hybrid CNN (HybridEdge-COVID), removing asymmetric-compression bias from the comparison. Performance is assessed via 5-fold stratified cross-validation (COVID-Xray-5k, n=5,000) and external validation on COVIDx CXR-3 (n=13,870). Bonferroni-corrected McNemar, TOST equivalence, DeLong AUC, calibration (ECE/Brier/MCE), and MC Dropout uncertainty tests are specified in the framework; their exact statistics require fold-level prediction files not available here and are reported as pending, not confirmed. Grad-CAM++ maps were validated by two radiologists on 75 COVID-19+ cases. Results: Under uniform compression, HybridEdge-COVID achieves 97.84±0.31% CV accuracy (95% CI 97.21-98.47%), AUC 0.981, MCC 0.957. ResNet18 (98.12%) and ResNet50 (98.23%) achieve nominally higher point-estimate accuracy; point-estimate McNemar p-values are provisionally non-significant for four of six baselines, with SqueezeNet provisionally inferior (p=0.004), pending exact computation. External validation yields 91.30% accuracy (95% CI 90.73-91.87%), AUC 0.943. On Raspberry Pi 4 (<USD 55): 8.93 s/100 images, 4.8 MB model, 47.2 MB peak RAM, Pareto-optimal among seven architectures. Dual-radiologist Grad-CAM++ validation yields kappa=0.71 (95% CI 0.61-0.81), 76.9% clinical feature consistency. McNemar/TOST decisions, DeLong Z-statistics, and calibration/MC Dropout values all remain provisional pending fold-level computation.Conclusions: The primary contribution is a fair, uniform compression-benchmarking methodology; HybridEdge-COVID is a secondary, illustrative architecture evaluated within it. Confirmation of equivalence, AUC, and calibration claims awaits fold-level analysis. Limitations: binary classification only, no prospective clinical validation, preliminary two-radiologist XAI, transformer baselines excluded, Grad-CAM++ not on-device; multi-centre prospective validation is required before clinical use.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.