Deformation measurement method for a multifunctional calibration component

Sep 2026 · Global Intelligent Industry Conference · Vol 14322, pp. 143223H - 143223H-11 · 0 citations · 13 references
Engineering

Abstract

To meet the high-precision calibration requirements of optical full-field strain measurement systems for standard deformation inputs, this paper proposes a deformation measurement method for a multifunctional calibration component based on laser interferometric measurement combined with synchronous angle measurement using an autocollimator. The component can generate first-order tilt deformation and second-order bending deformation. For the front surface, a laser interferometer is used to acquire the surface figure distributions in adjacent states, and the tilt variation and bending variation are extracted by surface-figure differencing. In the tilt mode, a plane mirror is mounted on the rear surface, and an autocollimator is used to synchronously measure the rear-surface tilt angle variation. Experimental results show that, under a set tilt variation of 1″, the average tilt measured by the interferometer is 0.878″, while that measured by the autocollimator is 0.870″, indicating good synchronous response between the front and rear surfaces of the calibration component. In the bending mode, the differential surface figure mainly exhibits a 0/90° astigmatism characteristic, with an average PV value of 0.550μm and an average astigmatism coefficient of 0.109, which is consistent with the expected hyperbolic surface figure characteristic. This method can realize quantitative measurement of the tilt and bending deformation modes of the calibration component, providing support for high-precision measurement applications of optical full-field strain measurement systems.

View source

Similar papers

Conference Sep 2026

Research on precise calibration method for tilt deformation

To address the insufficient calibration accuracy of deformation in current strain measurement systems, this study proposes and implements a dual-axis tilt deformation calibration method based on piezoelectric ceramic actuation. This method employs three piezoelectric ceramic actuators to construct a decoupled tilting m...

Le-Yuan Peng, Peng Chen, Hai-Rong Chen et al. · 0 citations
Open access Oct 2026

Metrological Set-Up and Procedure for Calibration of Displacement Transducers

High-precision displacement transducers are widely used in dimensional metrology due to their sub-micron accuracy and broad applicability. The increasing use of such sensors has led to a growing demand for SI-traceable calibration, requiring high-accuracy systems beyond the capabilities of commercial solutions. This pa...

Luka Čas, B. Ačko, R. Klobučar · 0 citations
Open access Sep 2026

Groove-Based Calibration of Multicore Fiber Bragg Grating Shape Sensors with Rotation-Angle Correction

Highlights A calibration method based on grooved curvature templates is developed for MCF-FBG shape sensors. The effective rotation angle used for sinusoidal fitting is corrected jointly for the four FBG responses. A 20 cm four-core MCF containing 200 femtosecond-laser-inscribed FBGs in 50 sensor planes is demonstrated...

Yi Jiang, M. Angelmahr, Ahmad Abdalwareth et al. · 0 citations
Open access Sep 2026

Mechanics-based measurement of one-dimensional deformation using multilayer embedded distributed optical-fibre strain sensing

Self-sensing structures require methods that convert internally measured strain into deformation with explicit mechanical meaning. This study presents a mechanics-based method for reconstructing two one-dimensional responses in 3D-printed polymer specimens containing embedded optical fibres: axial elongation under quas...

Peng-Fei Deng, Jie Sun, Tao Fu et al. · 0 citations
Open access Oct 2026

A prototype of a non-contact strain measurement system using tilted grating arrays

Evaluating mechanical strain is essential in engineering, whether for probing mechanical components or for maintaining structures such as bridges and wind power plants. Image-based strain measurement enables spatially resolved strain evaluation and, because it is non-contact, has the potential to make strain determinat...

A. Mathwieser, C. Girmen, N. Konig et al. · 0 citations
Oct 2026

Tilt and micro-shear calibration for holographic shearing interferometry

Holographic interferometry has been used since the 1970s and can be useful for characterizing aspheric and freeform surfaces. Holographic micro-shearing interferometry is a method by which a test surface can be compared to a holographic replica in a null, self-aligning measurement. Surfaces with large departures requir...

Demetrious R. Dowdell, Thomas G. Brown · 0 citations