Sep 2026· Italian National Conference on Sensors· Vol 26· 0 citations· 23 references
Medicine
Abstract
Highlights A calibration method based on grooved curvature templates is developed for MCF-FBG shape sensors. The effective rotation angle used for sinusoidal fitting is corrected jointly for the four FBG responses. A 20 cm four-core MCF containing 200 femtosecond-laser-inscribed FBGs in 50 sensor planes is demonstrated. Planar validation yielded tip-position errors of approximately 2–5 mm, compared with approximately 6–13 mm for conventional sine calibration. Abstract Fiber-optic shape sensors require accurate calibration of the spatial orientation and effective core distances of their sensing planes. We present a rotation-angle correction procedure for sinusoidal calibration of multicore fiber Bragg grating (MCF-FBG) shape sensors. The method is demonstrated using a constant-radius groove template and a single rotation stage. Within the groove fixture, groove–fiber friction, finite torsional stiffness, and non-ideal boundary conditions may contribute to deviations between the local sensor-plane rotation and the motor-imposed angle, resulting in distorted sinusoidal wavelength responses and biased curvature estimation. The proposed method addresses deviations from the assumed sinusoidal response by jointly correcting the effective rotation angle assigned to the four FBG responses in each sensor plane while leaving the measured wavelength shifts unchanged. The method was demonstrated using a 20 cm four-core single-mode fiber containing 200 femtosecond-laser-inscribed FBGs arranged in 50 sensor planes at 4 mm spacing. Quantitative validation with planar constant-curvature templates showed tip-position errors of approximately 2–5 mm, compared with approximately 6–13 mm for conventional sine calibration. An additional endpoint-position test of the 50-plane sensor yielded a mean error of 11.28 mm and an RMSE of 13.73 mm, compared with 19.03 mm and 21.55 mm, respectively, for conventional sine calibration. Additional non-planar bending tests qualitatively illustrated the sensor’s three-dimensional reconstruction capability. The results show that rotation-angle correction can improve calibration accuracy while retaining a single-rotation-stage groove fixture.
This paper presents a numerical study of a dual-parameter fiber Bragg grating (FBG) sensing system for simultaneous measurement of temperature and strain with effective cross-sensitivity mitigation. The proposed system employs two FBGs operating at distinct Bragg wavelengths of 1550 nm and 1555 nm and subjected to diff...
R. Dini, S. Saktioto· Science, Technology, and Com...· 0 citations
For conventional laser Fizeau phase-shifting interferometry, form measurement of ellipsoidal binary gratings remains challenging because of the discontinuous grating structure with groove depths exceeding half the illumination wavelength. In this study, we propose a spatio-temporal Fourier analysis method that extends...
Hui Xun, Sotero Ordoñes, Rong Su· Nanomanufacturing and Metrol...· 0 citations
To meet the high-precision calibration requirements of optical full-field strain measurement systems for standard deformation inputs, this paper proposes a deformation measurement method for a multifunctional calibration component based on laser interferometric measurement combined with synchronous angle measurement us...
Hai-Rong Chen, Peng Chen, Le-Yuan Peng et al.· Global Intelligent Industry...· 0 citations
The reliability of fiber-optic Bragg grating (FBG) sensors for monitoring reinforced concrete structures is determined by the efficiency of strain transfer across the sensor-structure interface. However, mounting methods are often chosen empirically, resulting in measurement deviations. This study quantitatively compar...
N. Smailov, Torekhan Zhadiger, B. Sekenov et al.· Fibers· 0 citations
This study presents a curve-based pixel-wise calibration method for microelectromechanical system (MEMS) mirror-based fringe projection profilometry (FPP) systems. The MEMS mirror, working at its resonant mode, exhibits dynamic deformation that bends the projected laser fringes into quadratic curves rather than ideal s...
Chang-Zhao Yan, Peng-Hong Shi, Min-Jie Zhu et al.· IEEE Transactions on Instrum...· 0 citations
We report a liquid-level sensor based on the air-cladding-mode band of a 37.5° tilted fiber Bragg grating (TFBG). Partial immersion increases the radiative loss of this mode band, and the liquid level is retrieved from the integrated area between its fitted upper and lower spectral envelopes. The sensor exhibits a sens...
Jia-Hao Dong, Zhen-Cheng Li, Kai-Wei Li et al.· Optics Letters· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.