A robust, fully automated, and cGMP-compliant production method for [11C]NOP-1A was successfully developed and validated for human use and facilitates broader clinical and translational investigation of the NOP receptor system in neuropsychiatric and neurological disorders.
Abstract
In vivo human studies of the nociceptin/orphanin FQ peptide (NOP) receptor have been limited by the availability and reliable production of suitable PET radioligands. [11C]NOP-1A is a high-affinity PET radioligand for imaging NOP receptors; however, reproducible production suitable for routine clinical use has been challenging. The aim of this study was to optimize, automate, and validate the radiosynthesis of [11C]NOP-1A for cGMP-compliant human PET imaging. We developed a fully automated loop radiomethylation method for the production of [11C]NOP-1A using the commercially available GE TRACERlab™ FXC Pro synthesis module and validated the process according to United States Food and Drug Administration (FDA) and United States Pharmacopeia (USP) requirements. Multiple radiolabeling conditions were evaluated using different bases and solvents. Optimal production was achieved using [11C]CH3I in the presence of sodium hydride (NaH) and dimethylformamide (DMF), resulting in reliable and reproducible synthesis with radiochemical conversion of up to 60%. Validation studies demonstrated successful production of [11C]NOP-1A with radiochemical purity ranging from 97.5 to 99.6%, molar activity of 79.4–162.9 GBq/μmol at end of synthesis, and a corrected radiochemical yield of 13 ± 2.5% relative to starting [11C]CO2. All quality control parameters met predefined acceptance criteria for human administration. A robust, fully automated, and cGMP-compliant production method for [11C]NOP-1A was successfully developed and validated for human use. This approach provides reliable routine production of [11C]NOP-1A and facilitates broader clinical and translational investigation of the NOP receptor system in neuropsychiatric and neurological disorders.
This study summarizes the automated, transition-metal-free radiosynthesis approach for producing [11C]LCM and its bioisosteric analogue [18F]FLCM, along with preliminary pharmacological and preclinical evaluations of these radiotracers can act as potent brain imaging radiotracer candidates. Radiosynthesis was carried o...
Cancer diagnosis increasingly requires molecular imaging agents with high tumor specificity and rapid biodistribution. [⁶⁸Ga]Ga-DOTA-FAPI-46 is a promising PET radiopharmaceutical that targets fibroblast activation protein (FAP); however, limited access to automated synthesis modules necessitates the development of rel...
J. Ardi, N. Rosilawati, H. A. Holik· Devotion : Journal of Resear...· 0 citations
We report on comparison of two automated production processes for radiolabelling and formulation of three different radiopharmaceuticals [
177
Lu]Lu-PSMA I&T, [
177
Lu]Lu-DOTA-TATE and [
90
Y]Y-DOTA-TOC. These processes were evaluated with and without C-18 solid phase extraction purification.
Rad...
Martin Kraihammer, C. Decristoforo, Adriana Knoll et al.· EJNMMI Radiopharmacy and Che...· 0 citations
Background/Objectives: Quantitative PET imaging of μ-opioid receptor (MOR) availability and pharmacologic engagement can advance in vivo studies of opioid receptor biology. We previously evaluated a series of 18F-labeled carfentanil analogs and prioritized the regioisomer [18F]fluorocarfentanil ([18F]FCFN) based on fav...
Evan Gallagher, Joseph W. Downey, Chi-Hyeon Yoo et al.· Pharmaceutics· 0 citations
Fully automated, multiple patient dose preparation of [68Ga]Ga-FAPI-4 was standardized using a commercial fixed tubing (non-cassette) based automated module namely Eckert and Ziegler 'Modular-Lab Standard' (EZ-ML). The routine production of [68Ga]Ga-FAPI-4 with consistent and reproducible decay corrected (dc) radiochem...
Sudeep Sahu, A. Chakraborty, Sangita Lad et al.· Applied Radiation and Isotop...· 0 citations
Inflammation is a protective biological response; however, prolonged or dysregulated inflammation is associated with different pathological disorders. Conventional imaging techniques primarily visualize structural changes, while molecular radiotracers strongly support the understanding of the functional and biochemical...