Skip to content
Open access

Dosimetric comparison of organs at risk exposure in multicatheter high-dose-rate interstitial brachytherapy vs. VMAT-based APBI for real patient treatment plans

Sep 2026 · Journal of Contemporary Brachytherapy · Vol 18, pp. 296 - 304 · 0 citations · 24 references
Medicine

TL;DR

APBI technique selection should be individualized based on anatomy and intramammary tumor bed location, and tVMAT provides a cardiac advantage mainly for left-sided upper/ outer quadrant tumors, and effectively minimizes low-dose lung exposure compared with continuous arc arrangements.

Abstract

Purpose To dosimetrically compare multicatheter interstitial high-dose-rate brachytherapy (MIBT) with two volumetric modulated arc therapy (VMAT) techniques, i.e., continuous (cVMAT) and tangential (tVMAT), for accelerated partial breast irradiation (APBI), specifically focusing on organs at risk (OARs) exposure. Material and methods Treatment plans of 50 early-stage breast cancer patients treated with interstitial multicatheter HDR brachytherapy (MIBT) were analyzed. Using identical CT datasets with catheters in situ and standardized contours, MIBT, cVMAT, and tVMAT plans were generated for each patient. For VMAT plans, planning target volume (PTV) was created by adding a 5 mm margin to clinical target volume (CTV). A uniform prescription dose of 32 Gy in 8 fractions was applied across all techniques. Dosimetric parameters were evaluated for target volumes, heart (including tumor quadrant sub-group analysis for left-sided cases), ipsilateral lung, skin, ribs, and non-target breast. Results VMAT safety margins increased target volume by 129% vs. MIBT. MIBT achieved superior sparing of non-target breast (median V50%: 15.84% vs. 27.66% tVMAT and 23.91% cVMAT, p < 0.0001), skin, and ribs (D1cc, p < 0.0001). For left-sided tumors, overall, tVMAT reduced mean heart dose vs. MIBT (0.38 Gy vs. 1.54 Gy, p < 0.0001). However, sub-group analysis revealed that this cardiac advantage was restricted to upper and outer quadrant tumors, with no significant differences for lower quadrant lesions. cVMAT delivered a high low-dose lung bath (V5%, 52.60%), which was significantly limited by tVMAT (19.26%) and MIBT (15.48%) (p < 0.0001). Conclusions APBI technique selection should be individualized based on anatomy and intramammary tumor bed location. MIBT optimizes sparing of healthy breast tissue, skin, and chest wall across all locations. Conversely, tVMAT provides a cardiac advantage mainly for left-sided upper/ outer quadrant tumors, and effectively minimizes low-dose lung exposure compared with continuous arc arrangements.

Read PDF

Similar papers

Sep 2026

Dosimetric comparison of automated noncoplanar volumetric-modulated arc therapy and intensity-modulated proton therapy for total scalp irradiation in angiosarcoma of the scalp.

OBJECTIVES To compare the dosimetric performance of HyperArc (HA) and intensity-modulated proton therapy (IMPT) for total scalp irradiation (TSI) in patients with angiosarcoma of the scalp (AS). METHODS HA and IMPT treatment plans were retrospectively generated for 27 patients with AS. Prescription doses of 70 and 56...

S. Inui, N. Tomita, T. Takaoka et al. · 0 citations
Sep 2026

Comprehensive and Comparative Dosimetric Characterization of VMAT and IMRT in Brain Cancer Treatment Planning: Target Coverage, OAR Sparing, Monitor Units, Dose Distribution, Low-Dose Volumes, and Delivery Efficiency

VMAT and IMRT were comparable in terms of target coverage and normal tissue protection, but VMAT needed fewer monitor units and had a significantly lower V20 with numerically lower V5 and V10 although these were not statistically significant.

Abbood Abbas Abbood · 0 citations
Open access Sep 2026

Dosimetric Impact of Deformable Image Registration versus Simple Summation in Multi-Fraction HDR Brachytherapy for Cervical Cancer under Standard Protocol

DIR-based dose accumulation resulted in significantly lower HR-CTV dose estimates compared with SS, while dose differences for the bladder and rectum remained minimal, and future research should correlate DIR-based dosimetry with clinical outcomes to support anatomically adaptive brachytherapy.

Chitchaya Suwanraksa, Bheampos Rojkitjanuruk, Tanapat Suwanpan et al. · 0 citations
Open access Sep 2026

Dosimetric Impact of Residual Intrafraction Motion in Gated MR-Guided Prostate SBRT With Focal Dose Intensification

Residual intrafraction motion produced directionally asymmetric coverage loss, with the largest effect on the boosted GTV, and motion-inclusive dose reconstruction enabled derivation of practical asymmetric margins that improved robustness while identifying the tradeoff between target coverage and delivery efficiency.

Ka-Ho Tam, S. Jogi, A. Sobremonte et al. · 0 citations
Open access Oct 2026

Cohort-specific dosimetric and delivery tradeoffs for proton dynamic arc vs. IMPT for breast and chest wall irradiation.

Compared with conventional intensity-modulated proton therapy for breast/chest wall irradiation across diverse clinical anatomies, DynamicArc achieved target coverage comparable to IMPT and improved robustness pass rates for selected targets.

Kristen McConnell, R. Rohe, Valeriane Mcneill et al. · 0 citations
Review Open access Oct 2026

Dosimetric comparison of the anisotropic analytical algorithm and Acuros XB for single-fraction cranial stereotactic radiosurgery with a 6 MV flattening filter-free beam

Stereotactic radiosurgery delivers an ablative single-fraction dose to small intracranial targets, and the reported dose depends on the calculation algorithm. This exploratory case series quantified the change in reported dosimetry when plans clinically finalised with the anisotropic analytical algorithm (AAA) were rec...

K. Utitsarn, Thepphithak Watthanasarn, Wirasinee Chaloemchawalit et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.