Skip to content
Open access

Cohort-specific dosimetric and delivery tradeoffs for proton dynamic arc vs. IMPT for breast and chest wall irradiation.

Oct 2026 · International Journal of Radiation Oncology, Biology, Physics · 0 citations · 12 references
Medicine

TL;DR

Compared with conventional intensity-modulated proton therapy for breast/chest wall irradiation across diverse clinical anatomies, DynamicArc achieved target coverage comparable to IMPT and improved robustness pass rates for selected targets.

Abstract

Purpose

To compare proton dynamic arc therapy (DynamicArc) with conventional intensity-modulated proton therapy (IMPT) for breast/chest wall irradiation across diverse clinical anatomies.

Methods

Forty patients were analyzed (10/cohort): tissue expanders, permanent implants, no reconstruction, and bilateral disease. DynamicArc plans used coplanar partial arcs (150-160°) with arc retracing; paired IMPT plans used 2-4 static fields. RayStation 2023BDTK-generated plans shared contours and prescriptions (50.4 Gy[RBE]/28; subset bilateral 42.56 Gy[RBE]/16) and were robustly optimized/evaluated (±5 mm setup,±3.5% range) with Monte Carlo dose calculation (0.5%uncertainty,40000ions/spot) and a 7.5cm range shifter. Target coverage and OAR endpoints were compared using Wilcoxon signed-rank tests with FDR correction. Additionally, robustness pass rates, LETd metrics, and estimated treatment times were compared.

Results

DynamicArc achieved target coverage comparable to IMPT and improved robustness pass rates for selected targets. In the expander cohort, DynamicArc improved coverage posterior to the expander port and increased coverage of the chest wall evaluation volume and nodal targets. Improved D95% was accompanied by increased target V105% in several targets. DynamicArc increased thyroid mean dose and skin V95% in multiple cohorts, although skin D2cc and skin V100% remained low. Focal hotspot metrics for the esophagus, heart, and LAD were largely unchanged, with LAD D0.03cc numerically lower though not statistically significant in the expander cohort. Ipsilateral lung V20 was generally similar, with a reduction in implant cases. Several unadjusted significant findings did not remain significant after FDR correction. High-dose CTV LETd was broadly comparable between techniques with changes in the tails of the distribution. DynamicArc increased spots, energy layers, and beam-on time, but estimated total treatment time was comparable after accounting for IMPT room entry and imaging.

Conclusion

DynamicArc achieved comparable target coverage with improved robustness in challenging anatomies, at the cost of increased V105%, thyroid mean dose, and skin V95% while maintaining comparable treatment times.

Read PDF

Similar papers

Oct 2026

Introduce 4π dynamic spot-scanning proton arc therapy (SPArc-4 π) for pancreatic cancer: a comparative planning study with IMPT

SPArc-4 π provides a promising proton planning strategy for pancreatic SBRT-SIB by preserving robust target coverage while improving gastrointestinal organ sparing and reducing predicted toxicity, and support further investigation of SPArc-4 π for safer dose escalation in LAPC.

Peng Chen, Pei-Lin Liu, Xiao-Da Cong et al. · 0 citations
Open access Sep 2026

Assessing Gamma Index Sensitivity to Selected Linear Accelerator Mechanical Errors Using Various Dosimetric Systems

Background: Volumetric modulated arc therapy (VMAT) for stereotactic body radiotherapy (SBRT) involves highly modulated dose distributions and steep dose gradients, increasing the importance of patient-specific quality assurance (QA). Gamma index analysis is widely used for comparing measured and treatment planning sys...

H. Ayata, G. Aydin, E. G. Ozgur et al. · 0 citations
Sep 2026

Dosimetric and robustness comparison of single- and double-arc volumetric-modulated arc therapy incorporating avoidance structures for prostate cancer with simulated bilateral hip prostheses.

This study compared the dosimetric performance and robustness of single-arc (SA) versus double-arc (DA) volumetric-modulated arc therapy (VMAT) incorporating avoidance structures (AS) for prostate cancer with simulated bilateral hip prostheses. A total of 15 prostate cancer cases without hip prostheses were retrospecti...

Takahiro Kato, T. Harada, Yuki Moriya et al. · 0 citations
Sep 2026

How robust are secondary dose algorithms for Patient-Specific quality assurance in modulated stereotactic Radiosurgery?

PURPOSE Accurate dose verification is essential in stereotactic radiosurgery (SRS), where small fields and steep dose gradients may amplify uncertainties, especially with complex techniques like multitarget single-isocenter VMAT. This technical note evaluated the robustness of two secondary dose calculation algorithms...

E. Mastella, K. E. Szilagyi, Joseph S. Perrine et al. · 0 citations
Nov 2026

Dosimetric impact of CBCT-guided online adaptive stereotactic body radiotherapy for prostate cancer: a 250-fraction retrospective analysis.

PURPOSE To quantitatively evaluate the dosimetric benefit of CBCT-guided online adaptive radiotherapy (ART) for prostate SBRT compared with non-adaptive treatment planning, with emphasis on target coverage preservation and organ-at-risk (OAR) sparing. METHODS AND MATERIALS Fifty prostate patients treated on the Varia...

A. Eldib, Andy T. Clark, J. Panetta et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.