Oct 2026· IEEE Sensors Journal· Vol 26, pp. 31435-31450· 0 citations· 50 references
Abstract
Cardiac arrest (CA) continues to be a leading cause of mortality during natural disasters. In postdisaster confined rescue operations, the effectiveness of conventional emergency devices is significantly constrained by their excessive size, operational complexity, and limited interoperability. To address these limitations, a back-mounted system integrating multiparameter real-time monitoring with automated life support is designed and developed for postdisaster emergency life support. The proposed device integrates four essential modules, namely, noncontact physiological monitoring, chest compression, respiratory support, and defibrillation, which are coordinated through an intelligent control system to ensure efficient intermodule collaboration and seamless data exchange. The device is designed in a modular backpack form, with dimensions of <inline-formula> <tex-math notation="LaTeX">$37\times 28\times 60$ </tex-math></inline-formula> cm and a total weight of 14.9 kg, thereby ensuring portability and rapid deployment. The noncontact monitoring module, utilizing red/green/blue (RGB) and infrared imaging, enables the real-time acquisition of multiple vital signs. The chest compression module provides adjustable parameters with high-precision control. Both pressure- and flow-regulated modes are incorporated into the ventilatory support module; a 30:2 cardiopulmonary resuscitation (CPR) ventilation ratio is supported, and the target ventilation pressure can be set using only three adjustments. The defibrillation module integrates rapid R-wave detection with adaptive impedance matching to mitigate the risk of myocardial injury. Furthermore, real-time data sharing and intermodule collaboration are facilitated through Wi-Fi connectivity. Experimental results showed that the noncontact monitoring module enabled simultaneous estimation of multiple physiological parameters under the tested conditions. The system achieved a chest compression rate of <inline-formula> <tex-math notation="LaTeX">$100.13~\pm ~0.87$ </tex-math></inline-formula> cpm and a compression depth of <inline-formula> <tex-math notation="LaTeX">$49.95~\pm ~0.32$ </tex-math></inline-formula> mm. During ventilation, the tidal volume (VT) and peak inspiratory pressure were <inline-formula> <tex-math notation="LaTeX">$382.40~\pm ~2.85$ </tex-math></inline-formula> mL and <inline-formula> <tex-math notation="LaTeX">$10.01~\pm ~0.03$ </tex-math></inline-formula> cmH<sub>2</sub>O, respectively. During defibrillation, the energy-delivery error remained within ±5%, with a synchronization delay of 1 ms. By integrating these advances, the system establishes an intelligent, portable, and effective solution tailored for disaster-site and prehospital emergency care.
Abstract Objective: Triage and data transfer are critical to the medical management of mass-casualty incidents (MCIs). However, the chaotic nature of such events makes it difficult to classify casualties according to structured triage protocols. Furthermore, even when triage is implemented effectively, communication di...
Ismail Tayfur, Perihan Şimşek, Mert Bal et al.· Prehospital and Disaster Med...· 0 citations
A human-in-the-loop communication support system for telemedicine monitoring of kidney transplant recipients and demonstrates the potential of automated communication support systems to assist routine telemedicine workflows while maintaining human oversight of patient communication.
Roland Roller, A. Ravichandran, Tillmann Breitenstein et al.· Frontiers in Digital Health· 0 citations
A digital-twin-based visual monitoring and automated maintenance decision-support system for substation equipment that links diagnostic analytics with decision-support and supervisory automation-control workflows, supporting earlier intervention and more consistent operator responses without bypassing certified protect...
Jian-Ping Xu, Zhi Miao, Wan-Xin Zhao et al.· International Conference on...· 0 citations
Acute respiratory failure (ARF) requires rapid intervention to prevent patient deterioration and life-threatening complications. Early respiratory support through prehospital Continuous Positive Airway Pressure (CPAP) has been shown to improve ARF outcomes. However, existing CPAP devices present technical barriers for...
Federica Ciceri Negri, Eleonora Salurso, Giuseppe Giardina et al.· Biomedical Engineering Lette...· 0 citations
The results demonstrate the feasibility of deploying a distributed thermal IoMT system in a real intensive care unit under hospital information technology governance, offering a preliminary reference model for on-premise, nonintrusive thermal sensing infrastructures in critical care, pending validation across additiona...
Eva Avilés, J. Lafuente, Samuel González et al.· Journal of medical systems· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.