Sep 2026· International Conference on Intelligent Transportation Systems and Automation Control· Vol 14368, pp. 143682L - 143682L-8· 0 citations· 19 references
Engineering
TL;DR
A digital-twin-based visual monitoring and automated maintenance decision-support system for substation equipment that links diagnostic analytics with decision-support and supervisory automation-control workflows, supporting earlier intervention and more consistent operator responses without bypassing certified protection functions is developed.
Abstract
The digitalization of modern substations has transformed automation-control infrastructures into cyber-physical environments that continuously generate multi-rate and heterogeneous monitoring data. Conventional platforms, however, usually present isolated alarms and cannot maintain an interpretable link among field assets, virtual models, degradation evidence, and maintenance actions. This paper develops a digital-twin-based visual monitoring and automated maintenance decision-support system for substation equipment. The system integrates equipment geometry and topology, synchronized sensor streams, robust residual modeling, an explicit health-index function, risk scoring, and three-dimensional operation-and-maintenance visualization. All model functions, feature weights, correction gains, thresholds, and calibration rules are specified. A reproducible 110-kV prototype case contains 8,640 samples per continuous channel and 240 labeled event windows. On a held-out set of 48 windows, the proposed method achieved 93.8% accuracy, 95.8% recall, and a 93.9% F1 score; its median event-detection delay was 3.5 min, compared with 12.0 min for threshold-only monitoring. The results demonstrate improved multi-source interpretation and maintenance traceability, while field validation over multiple seasons remains necessary. By converting synchronized health evidence into prioritized maintenance recommendations and traceable alarm explanations, the proposed system links diagnostic analytics with decision-support and supervisory automation-control workflows, supporting earlier intervention and more consistent operator responses without bypassing certified protection functions.
Civil infrastructure such as bridges, buildings, tunnels and dams experiences performance degradation during long-term service because of loading actions, environmental attack and material ageing, and therefore requires continuous structural health monitoring (SHM). Conventional monitoring, however, remains inadequate...
Yuxuan Fei· Applied and Computational En...· 0 citations
Multimodal sensing provides a mature foundation for elevator monitoring, while visual records, equipment-state records, and operational responses still need to be connected in many deployed community systems. This study develops an event-level closed-loop governance framework for that connection. Continuous visual dete...
This study addresses the persistent challenge of coordinate drift in substation monitoring systems, where prolonged operation leads to progressive deviations from preset configurations. An optimized BN-FTA framework that integrates Bayesian Networks (BNs) with Fault Tree Analysis (FTA) is proposed to improve anomaly de...
Substation operation and maintenance (O&M) increasingly depends on heterogeneous sensing, three-dimensional asset models, remote expert collaboration, and auditable automation support. However, conventional mobile maintenance applications still separate equipment state, spatial context, safety procedures, expert guidan...
Hao-Bo Li, Zu-Yue He, Mei-Han Chen et al.· International Conference on...· 0 citations
An edge-deployable framework that integrates multimodal perception, health reasoning, maintenance decision, and safety-supervised closed-loop control is developed and establishes a practical and auditable pathway from multimodal inspection evidence to bounded automated control.
Tian-Qi Zhang, Liang Gao, Zi-Han Wang et al.· International Conference on...· 0 citations
This paper presents a multi-source data-fusion framework for fault diagnosis and early warning of relay protection secondary circuits in smart substations. The proposed method integrates seven data sources—SV statistics, GOOSE statistics, IED self-check records, MMS alarms, physical-link measurements, time-synchronizat...
Ke-Fei Xiao, Zhao-Xu Huang· Journal of Physics, Conferen...· 0 citations