Skip to content

Introduce 4π dynamic spot-scanning proton arc therapy (SPArc-4 π) for pancreatic cancer: a comparative planning study with IMPT

Oct 2026 · Physics in Medicine and Biology · Vol 71, pp. 205019 · 0 citations · 47 references
Medicine Physics

TL;DR

SPArc-4 π provides a promising proton planning strategy for pancreatic SBRT-SIB by preserving robust target coverage while improving gastrointestinal organ sparing and reducing predicted toxicity, and support further investigation of SPArc-4 π for safer dose escalation in LAPC.

Abstract

Objective. Stereotactic body radiotherapy with a simultaneous integrated boost (SBRT-SIB) for locally advanced pancreatic cancer (LAPC) is constrained by the proximity of serial gastrointestinal organs at risk (OARs). Conventional intensity-modulated proton therapy (IMPT) relies on a limited number of fixed beam angles, which may restrict dose shaping around these critical structures. This study evaluated whether non-coplanar spot-scanning proton arc therapy (SPArc-4 π) could improve OAR sparing while preserving robust target coverage. Approach. 10 patients with LAPC were retrospectively selected in this study. For each patient, SBRT-SIB plans were generated using conventional IMPT and SPArc-4 π. Plan robustness was assessed across 21 uncertainty scenarios. Target coverage, conformity, OAR doses, estimated delivery time, and Lyman–Kutcher–Burman normal tissue complication probability for four gastrointestinal endpoints were compared using the Wilcoxon signed-rank test. Main results. SPArc-4 π maintained target coverage comparable to IMPT, with similar clinical target volume (CTV) and boost-volume coverage, while CTV conformity improved with SPArc-4 π (conformity index: 0.50 vs. 0.56; p = 0.02). SPArc-4 π significantly reduced maximum dose (Gy(RBE)) to the stomach (30.01–24.53), duodenum (35.14–33.14), bowel (32.60–28.91), and spinal cord (15.38 to 5.58; all p ⩽ 0.01). Predicted toxicity decreased across all four gastrointestinal endpoints: gastric bleed risk decreased from 8.19% to 6.15%, grade ⩾3 gastrointestinal toxicity from 3.91% to 3.81%, ulceration/perforation from 0.03% to 0.01%, and diarrhea from 24.14% to 22.34% (all p⩽0.005). All plans met robustness criteria. The main trade-off was delivery efficiency, with SPArc-4 π requiring approximately 2–3 min longer delivery time than IMPT. Significance. SPArc-4 π provides a promising proton planning strategy for pancreatic SBRT-SIB by preserving robust target coverage while improving gastrointestinal organ sparing and reducing predicted toxicity. These findings support further investigation of SPArc-4 π for safer dose escalation in LAPC.

View source

Similar papers

Open access Oct 2026

Cohort-specific dosimetric and delivery tradeoffs for proton dynamic arc vs. IMPT for breast and chest wall irradiation.

Compared with conventional intensity-modulated proton therapy for breast/chest wall irradiation across diverse clinical anatomies, DynamicArc achieved target coverage comparable to IMPT and improved robustness pass rates for selected targets.

Kristen McConnell, R. Rohe, Valeriane Mcneill et al. · 0 citations
Nov 2026

Dosimetric impact of CBCT-guided online adaptive stereotactic body radiotherapy for prostate cancer: a 250-fraction retrospective analysis.

PURPOSE To quantitatively evaluate the dosimetric benefit of CBCT-guided online adaptive radiotherapy (ART) for prostate SBRT compared with non-adaptive treatment planning, with emphasis on target coverage preservation and organ-at-risk (OAR) sparing. METHODS AND MATERIALS Fifty prostate patients treated on the Varia...

A. Eldib, Andy T. Clark, J. Panetta et al. · 0 citations
Open access Oct 2026

RapidArc dynamic versus IMRT and VMAT for endometrial cancer SIB radiotherapy

Radiotherapy with simultaneous integrated boost (SIB) for endometrial cancer requires highly conformal dose distributions to reduce toxicity. RapidArc Dynamic (RAD), a novel technique combining dynamic arc delivery with strategic gantry pauses, may improve organ-at-risk (OAR) sparing. This study aimed to c...

Yu-Tong Zhao, Xin-Qiang Zhang, Xiao-Shen Wang et al. · 0 citations
Open access Sep 2026

Forward-Planned Multisegmented Technique in Resource-Limited Settings: A Feasible Dosimetric Upgrade for 3D-CRT in Locally Advanced Nasopharyngeal Carcinoma

In resource-limited settings, intensity-modulated radiotherapy (IMRT) is often unavailable, forcing reliance on three-dimensional conformal radiotherapy (3D-CRT) for advanced nasopharyngeal carcinoma (NPC). This limits curative potential due to challenges in sparing organs-at-risk (OARs) while covering complex target v...

AS Badiane, M. Dieng, Lef Edimo et al. · 0 citations
Open access Oct 2026

Multi-criteria proton treatment planning incorporating spot boosting for prompt gamma in-vivo range verification

Objective. Prompt gamma (PG) detection enables beam range verification and margin reduction in proton therapy, but its effectiveness is limited by counting statistics. Spot boosting has been proposed to enhance the signal-to-noise ratio by increasing the number of protons in selected spots of a pencil beam scanning tre...

Mara Schubert, Ze Huang, M. Pinto et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.