Sep 2026· Journal of Case Reports and Images in Otolaryngology· 0 citations· 5 references
TL;DR
This case adds to the limited literature by demonstrating successful cochlear implantation in a patient with established bilateral VIM DBS, including successful intraoperative device testing, substantial postoperative improvement in speech perception, and sustained compatibility between the cochlear implant and DBS systems over two years of follow-up.
Abstract
Introduction: Cochlear implantation (CI) in patients with preexisting bilateral deep brain stimulation (DBS) systems is rarely performed because of concerns regarding electromagnetic interference, device malfunction, telemetry disruption, and intraoperative safety. We report the successful cochlear implantation of a patient with bilateral ventral intermediate nucleus (VIM) DBS, with two years of clinical and audiologic follow-up demonstrating sustained outcomes without DBS-related complications.
Case Report: A 79-year-old man with progressive bilateral sensorineural hearing loss and medically refractory essential tremor treated with staged bilateral VIM DBS underwent right cochlear implantation after obtaining limited benefit from hearing aids. Preoperatively, right hearing-aid testing demonstrated consonant-nucleus-consonant (CNC) word recognition of 16% and an AzBio score of 33%. Right cochlear implantation was performed using a Cochlear Americas CI632 electrode array. Full electrode insertion was achieved, with normal intraoperative neural response telemetry and no surgical complications. Postoperatively, speech perception improved substantially, with CNC word recognition increasing to 74% at five months and 70% at nine months. Bimodal AzBio sentence scores were 84% at five months and 72% at nine months. During two years of follow-up, there were no episodes of DBS malfunction, telemetry interference, programming difficulty, or cochlear implant device failure.
Conclusion: Cochlear implantation can be safely performed in patients with preexisting bilateral DBS systems with careful perioperative planning and device management. This case adds to the limited literature by demonstrating successful cochlear implantation in a patient with established bilateral VIM DBS, including successful intraoperative device testing, substantial postoperative improvement in speech perception, and sustained compatibility between the cochlear implant and DBS systems over two years of follow-up.
RACIS represents a maturing, reproducible approach to atraumatic cochlear implantation that reduces inter-operator variability and improves the consistency of electrode placement, and is better established than its long-term functional benefit.
G. Gersdorff, Séverine Camby, Philippe Lefebvre· Frontiers in Audiology and O...· 0 citations
OBJECTIVE
To report the technical feasibility and early outcome of cochlear implantation using a retrofacial approach (RFA) in a child with an inner ear malformation and limited access to the round window.
METHODS
A 3-year-old child with bilateral profound sensorineural hearing loss presented with an incomplete parti...
K. Messaoudi, S. Benmeziane, I. Bazouzi et al.· European Annals of Otorhinol...· 0 citations
To report the first Chinese case of complex mosaic neurofibromatosis type 2 (NF2)—recently reclassified as NF2-related schwannomatosis—in a patient presenting with concurrent severe visual impairment and an intracochlear schwannoma, and to evaluate the clinical efficacy and strategic priority of tumor-preserving in...
Bo-Xiang Zhuang, Lin-Ling Fu, Dan-Dan Wang et al.· Journal of Otology· 0 citations
The findings suggest that cochlear implantation may be considered in selected patients with substantial residual hearing when conventional hearing aids provide insufficient functional benefit, but broader conclusions regarding cochlear implant candidacy cannot be drawn from a single case.
H. Skarżyński, E. Włodarczyk, A. Lorens et al.· Journal of Clinical Medicine· 0 citations
OBJECTIVE
To evaluate the efficacy of EMPES [Early implantation, Modiolar Proximity (MP), and Early Switch-on] approach in bilateral cochlear nerve (CN) aplasia.
STUDY DESIGN
Retrospective cohort study.
SETTING
Tertiary referral center.
PATIENTS
Forty-six children (86 ears) with bilateral CN aplasia underwent coc...
Suji Jeong, Yehree Kim, Hyun Seong Kim et al.· Otology and Neurotology· 0 citations
In children with normal cochlear anatomy, slim modiolar electrodes were associated with superior long-term speech outcomes, lower stimulation requirements, greater device use, and improved intracochlear stability compared with lateral wall electrodes.
F. Zawawi, Afnan F. Bukhari, Mohamed Garrada· Otology and Neurotology· 0 citations