Skip to content
Review Open access

Hearing preservation in cochlear implantation: a comprehensive review with emphasis on atraumatic and robot-assisted electrode insertion

Sep 2026 · Frontiers in Audiology and Otology · Vol 4 · 0 citations · 155 references

TL;DR

RACIS represents a maturing, reproducible approach to atraumatic cochlear implantation that reduces inter-operator variability and improves the consistency of electrode placement, and is better established than its long-term functional benefit.

Abstract

Preservation of residual hearing has become a central objective in modern cochlear implantation (CI), enabling electro-acoustic stimulation and improved speech, music, and noise perception. Achieving this goal depends critically on minimizing intracochlear trauma during electrode insertion. Despite atraumatic surgical techniques, a substantial proportion of recipients lose part or all of their residual hearing over time, and manual insertion remains constrained by human motor variability. This review synthesizes current evidence on the mechanisms of insertion-related cochlear trauma and evaluates surgical, pharmacological and technological strategies for hearing preservation, with particular attention to the role of robot-assisted cochlear implantation surgery (RACIS). A narrative synthesis of experimental, histopathological, and clinical literature addressing atraumatic electrode insertion principles, electrode design, insertion kinematics, perioperative corticosteroids, and robotic insertion systems (including RobOtol, OTODRIVE, and iotaSOFT). PubMed/MEDLINE, Embase and Web of Science were searched from January 1980 to May 2026, with Google Scholar and the reference lists of key articles as supplementary sources. Preclinical data are reported separately from clinical data. Insertion-related trauma, including scalar translocation, electrode tip fold-over, and basilar membrane rupture, triggers inflammation, fibrosis, and neo-osteogenesis, compromising both residual hearing and long-term neural survival. Insertion speed and trajectory stability are identified as key modulators of intracochlear force and pressure generation. In cadaveric and in vitro models, robotic systems achieve significantly lower and more reproducible insertion angular errors and force profiles than manual insertion, with higher rates of full scala tympani placement and lower trauma scores. Clinical studies suggest improved hearing preservation (up to 85% vs. 71% following manual insertion in a non-randomized comparative study). Meta-analytic data report an overall RACIS procedural success rate of 97.2% and a complication profile comparable to conventional surgery. Postoperative impedance trends are also more stable, suggesting attenuated fibro-inflammatory remodeling. Pooled hearing preservation estimates, however, show very high statistical heterogeneity (I2 = 98.41%). RACIS represents a maturing, reproducible approach to atraumatic cochlear implantation that reduces inter-operator variability and improves the consistency of electrode placement. Integration with real-time intraoperative monitoring, such as electrocochleography, offers further potential for adaptive, personalized insertion strategies. At present, the technical superiority of robotic insertion is better established than its long-term functional benefit. Future randomized controlled studies incorporating long-term functional outcomes, cost-effectiveness and anatomical imaging are required to establish the true clinical benefit of RACIS.

Read PDF

Similar papers

Review Oct 2026

Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques.

OBJECTIVE This study reviewed the early shifts in low-frequency hearing for cochlear implant (CI) hearing preservation candidates who underwent cochlear implantation using either manual or robotic-assisted insertion of the electrode array and evaluated possible contributing factors such as angular insertion depth (AID)...

Carlos A. Perez-Heydrich, Margaret T. Dillon, Elena Quinonez Del Cid et al. · 0 citations
Open access Sep 2026

Successful cochlear implantation in a patient with preexisting bilateral deep brain stimulation: A case report with two-year follow-up

This case adds to the limited literature by demonstrating successful cochlear implantation in a patient with established bilateral VIM DBS, including successful intraoperative device testing, substantial postoperative improvement in speech perception, and sustained compatibility between the cochlear implant and DBS sys...

N. Thapa, Marissa J. Rabadi, C. Jabour et al. · 0 citations
Review Open access Sep 2026

Evaluation of tip fold over in 1,575 cochlear implant electrode arrays

Objective Cochlear implant (CI) surgery aims to achieve atraumatic electrode array insertion to preserve residual hearing and optimize outcomes. Tip fold-over, a mechanical complication during insertion, can compromise stimulation effectiveness and may require reinsertion or revision surgery. This study investigates th...

G. Magradze, Jonas Schröfel, L. Fries et al. · 0 citations
Oct 2026

Optimizing Cochlear Implant Outcomes in Cochlear Nerve Aplasia: The EMPES Protocol (Early Implantation, Modiolar Proximity, and Early Switch-On).

OBJECTIVE To evaluate the efficacy of EMPES [Early implantation, Modiolar Proximity (MP), and Early Switch-on] approach in bilateral cochlear nerve (CN) aplasia. STUDY DESIGN Retrospective cohort study. SETTING Tertiary referral center. PATIENTS Forty-six children (86 ears) with bilateral CN aplasia underwent coc...

Suji Jeong, Yehree Kim, Hyun Seong Kim et al. · 0 citations