Skip to content
Review Open access

User validation of an AI-assisted ultrasound guidance system for rapid vascular access.

Sep 2026 · European Radiology · 0 citations · 10 references
Medicine

TL;DR

The AI-GUIDE-LL enables rapid, accurate femoral vessel localization and needle insertion among novice clinicians, supporting feasibility for field-forward military and point-of-care civilian settings.

Abstract

Objectives

Vascular cannulation enables life-saving resuscitation in traumatic hemorrhage. The AI-GUIDE-LL is a handheld ultrasound-guided robotic device enabling inexperienced medical providers to obtain femoral vascular access. Device efficacy has been demonstrated in expert-operated porcine models, though performance among inexperienced operators and in humans is unknown. We evaluated the AI-GUIDE-LL's performance among novice clinicians to target human femoral vessels and accurately deploy needles in phantoms.

Materials And Methods

This single-site prospective study recruited medical professionals without ultrasound-guided procedural experience. Users attempted femoral artery needle insertion in five human CT-derived inguinal phantoms using fluid aspiration as the reference standard, with three needle insertions permitted per phantom. Subsequently, they used the device to target healthy human volunteer femoral vessels, assessing target vessel localization and common femoral segment identification. Success was defined by expert review of ultrasound images and video recordings.

Results

Thirty clinicians (seven advanced practice providers, five EMTs, nine physicians, and nine registered nurses) achieved correct needle insertion in phantoms in 93% (140/150) of trials, with a median completion time of 44 s and a mean of 1.1 attempts. 28 volunteers were scanned by 28 clinicians. Clinicians successfully targeted 97% (93/96) of vessels with a median time of 25 s. Common femoral segment confirmation was achieved in only 20% of trials.

Conclusion

The AI-GUIDE-LL enables rapid, accurate femoral vessel localization and needle insertion among novice clinicians, supporting feasibility for field-forward military and point-of-care civilian settings. Reliable segment-specific localization above the femoral bifurcation, necessary for large-bore arterial procedures, remains an important limitation requiring further work. KEY POINTS Question AI-GUIDE-LL is a handheld robotic system that integrates artificial intelligence and ultrasound guidance to assist non-expert users in performing femoral vascular access for rapid point-of-care interventions. Findings Clinicians with limited ultrasound experience successfully localized femoral vessels, achieving 93% phantom needle insertion success and 97% target vessel localization in human trials. Clinical relevance AI-GUIDE-LL may enable clinicians with limited ultrasound training to perform timely femoral cannulation for life-saving interventions, including fluid resuscitation in traumatic hemorrhage, particularly in military or resource-limited environments.

Read PDF

Similar papers

Review Open access Nov 2026

Safety and Usability of a Novel, Robotic Assistance System for Echocardiographic Examination

Background: Transthoracic echocardiography (TTE) is essential for modern cardiac diagnostics, yet it is difficult to access in remote areas. Remotely operated robotic-assisted ultrasound may enable access to services in rural and remote locations, while also improving ergonomics for the sonographer. This study evaluate...

Cathy West, K. Guppy-Coles, J. Armstrong et al. · 0 citations
Open access Oct 2026

Novice users of handheld cardiac ultrasound: comparative performance of two artificial intelligence guidance systems

Real-time artificial intelligence (AI) guidance may enable imaging-naïve users to acquire images suitable for diagnosis using handheld focused cardiac ultrasound (FoCUS). To compare image quality and diagnostic performance of novice-acquired FoCUS scans using two commercially available AI-guidance handheld...

M. Killalea, M. Gulati, J. Kovac et al. · 0 citations
Open access Oct 2026

3D printed robotic tooling for fluoroscopy-guided vascular access: emerging implications for cardiology practice

A radiation efficiency paradox in femoral arterial access is quantified, where fluoroscopy time increases modestly but operator dose rate falls, and dose-per-minute metrics that better reflect staff risk are proposed that better reflect staff risk.

M. Khan, D. O. Toole · 0 citations
Oct 2026

Evaluation of a porcine tissue-based simulator for teaching ultrasound-guided PICC placement.

BACKGROUND Ultrasound-guided peripherally inserted central catheter (PICC) placement requires stable probe handling and continuous needle-tip tracking, yet novice nurses have limited opportunities for repeated clinical practice. OBJECTIVE This study aimed to evaluate the association between porcine tissue-based simul...

Le-Yi Deng, Jiao He, Li Gao et al. · 0 citations
Sep 2026

Educational utility of a 3D-printed canine hepatic artery phantom for CT bolus tracking training

The study findings support the integration of high-fidelity phantom use into veterinary radiology curricula, to bridge the gap between theory and clinical practice, and standardising technical proficiency in veterinary radiology.

Keonyeong Min, Dong-Woo Chang, Namsoon Lee · 1 citation
Preprint Nov 2026

Clinician-AI Collaboration in Endovascular Neurointerventions: In-Vitro User Study of Copilot Assistance Modes for Robotic Navigation Across the Autonomy Spectrum

Mechanical thrombectomy (MT) is an effective treatment for acute ischemic stroke, yet access remains limited by the availability of neurointerventional expertise. Telerobotic and AI-assisted systems may help address this challenge, but it remains unclear how clinicians interact with different levels of autonomy and how...

N. Fischer, Harry Robertshaw, S. M. Hadi Sadati et al. · 0 citations