Oct 2026· Dental and Medical Problems· pp. 0-0· 0 citations
Medicine
TL;DR
While the fully dentate model showed no significant differences in trueness among the scanners, it, along with the abutment model, yielded the highest overall accuracy, whereas the edentulous and scanbody models exhibited greater deviations.
Abstract
Background
The accuracy of intraoral scanners (IOSs) has been widely reported. However, studies comparing their performance under different clinical conditions are lacking.
Objectives
The aim of the present study was to compare the trueness and precision of 5 IOSs across 4 anatomically distinct models simulating common clinical conditions: edentulous; abutment; orthodontic (fully dentate); and scanbody scenarios.
MATERIAL AND
Methods
An in vitro study was conducted using 4 maxillary models representing different clinical configurations. Five IOSs (AORALSCAN 3, TRIOS 5, ViSIOScan WL, iTero Element 5D Plus, and DEXIS IS 3800) were evaluated. Each model was scanned 10 times with each scanner, and a laboratory desktop scanner was used as the reference for trueness. Accuracy was quantified using the root mean square (RMS) deviation values, with a clinical acceptability threshold of 0.25 mm. Superimposition and deviation analyses were performed using three-dimensional (3D) software, and statistical comparisons were conducted using ANOVA and Scheffé's post hoc test.
Results
Except for ViSIOScan WL in the scanbody model, all tested scanners demonstrated accuracy values below 0.1 mm. Significant differences in trueness and precision were observed both between the scanners and across the clinical scenarios (p < 0.05). Overall, AORALSCAN 3 and iTero Element 5D Plus consistently demonstrated the best performance. The abutment and fully dentate models showed the highest accuracy, whereas the edentulous and scanbody models exhibited greater deviations, particularly for ViSIOScan WL and DEXIS IS 3800.
Conclusions
Despite most IOSs achieving accuracy below 0.1 mm, substantial variability was observed depending on the scanner type and the anatomical context. AORALSCAN 3 and iTero Element 5D Plus consistently demonstrated superior trueness and precision across most models. While the fully dentate model showed no significant differences in trueness among the scanners, it, along with the abutment model, yielded the highest overall accuracy. The edentulous and scanbody models posed greater challenges.
Background: To evaluate the accuracy and precision of digital dental
impressions using the Polygon File Format (PLY) across three intraoral
scanners.
Methods: A maxillary arch resin model with reference points was scanned
10 times using the intraoral scanners (3Shape TRIOS 5, Medit i900, Cameo
Elegant 3) and a laborato...
Saud J. Dizayee· European Journal of Prosthod...· 0 citations
The aim of this study was to conduct a comparative in vivo and in vitro assessment of the accuracy of intraoral scanners in generating a virtual dental arch model during splint therapy. The study design comprised a clinical (in vivo) phase and a laboratory (in vitro) phase. In the first phase, the trueness of scanning...
I. Naidanova, E. Bulycheva, D. S. Bulycheva· CLINICAL DENTISTRY· 0 citations
Objectives: This in vitro study aimed to compare the accuracy of intraoral scanning and
photogrammetry-based acquisition methods for full-arch implant-supported rehabilitations
involving four and six implants.
Methods: An acrylic edentulous mandible was used to simulate the clinical setting. Implant
positions were acqu...
R. Pinto, J. Martins, José Navarro et al.· Revista Portuguesa de Estoma...· 0 citations
Background: Accurate three-dimensional (3D) recording of implant positions is fundamental to achieving passive fit and long-term success of implant-supported prostheses. The growing adoption of digital intraoral scanners (IOS) necessitates rigorous clinical evaluation of their accuracy relative to established conventio...
Rahul Ranjan, Anju Aggarwal, Punit R. S. Khurana et al.· International Journal of Dru...· 0 citations
OBJECTIVES
To evaluate the effects of different scanning modes of intraoral scanners (scan-only versus restoration type selected) on STL triangle counts and to assess the influence of STL triangle counts on trueness across different scanner systems.
METHODS
A typodont model with 3 prepared teeth was scanned with 15 s...
Hale Arikan Kalayci, Simge Alıcı, Gülçe Çakmak et al.· E -journal of dentistry· 0 citations
Within the limitations of this in vitro study, iTL demonstrated higher trueness and precision than the other IOSs tested, whereas PEEK and hybrid ISBs demonstrated higher trueness for 3-unit implant scans.
Bahar Gurpinar, Burcu Kanat-Ertürk, Mehmet Karakuzu et al.· The Journal of prosthetic de...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.