R2* quantification was less sensitive to respiratory motion at 0.55T than at 3T, while PDFF remained relatively insensitive, and time-resolved reconstruction provided additional robustness to bulk motion.
Abstract
Purpose: Free-breathing multi-echo MRI enables hepatic PDFF/R2* quantification without breath-holds, but respiratory motion can affect R2* estimation through motion-induced field variations. We investigated whether respiratory motion sensitivity is reduced at 0.55T versus 3T and developed a time-resolved free-breathing 4D MRI approach without respiratory binning. Methods: A navigator-embedded multi-echo stack-of-stars sequence was implemented. Ten subjects were scanned during free breathing and deliberate bulk motion at both 3T and 0.55T. Data were reconstructed using motion-averaged, motion-resolved, and time-resolved approaches. Quantitative performance was also evaluated in a PDFF/R2* phantom using Cartesian and radial acquisitions. Results: Phantom experiments showed close radial-Cartesian agreement for R2* and PDFF at 3T. At 0.55T, R2* showed good agreement over the low-to-moderate range but higher uncertainty at high R2*, where larger radial-Cartesian PDFF differences were also observed. R2* was substantially less sensitive to respiratory motion at 0.55T than at 3T, whereas PDFF was relatively insensitive at both field strengths. Under bulk motion, time-resolved reconstruction provided robust R2* and PDFF measurements, with particularly high consistency between free-breathing and bulk-motion acquisitions at 0.55T. Conclusion: R2* quantification was less sensitive to respiratory motion at 0.55T than at 3T, while PDFF remained relatively insensitive. Time-resolved reconstruction provided additional robustness to bulk motion. Reduced susceptibility effects at 0.55T and time-resolved reconstruction may provide complementary advantages for motion-robust free-breathing hepatic R2* and PDFF quantification.
PURPOSE
This study aimed to assess the feasibility of QSM in the human kidney during free-breathing using respiratory gating for motion compensation.
METHODS
Renal imaging of 15 healthy volunteers was performed using an axial multi-echo GRE sequence on a 3 T MRI scanner. Each subject was scanned once during breath-ho...
Matthias Deitermann, Birte Sehlmeyer, T. Thiel et al.· Magnetic Resonance in Medici...· 0 citations
PURPOSE
Quantitative imaging on mid-field (0.55 T) MRI systems can suffer from poor precision due to low SNR. This work presents an MRF pulse sequence optimized with Cramer-Rao lower bound (CRLB) and combined with a multi-echo deep image prior (DIP) reconstruction for co-registered T1/T2/T2*/PDFF mapping in the liver a...
Tom Griesler, Jesse I. Hamilton, Evan Cummings et al.· Magnetic Resonance in Medici...· 0 citations
PURPOSE
To develop a technique for joint measurement of fat and water-specific longitudinal relaxation rates (R1f and R1w), effective transverse relaxation rate (R2∗), and proton density fat fraction (PDFF) combining the Multi-Echo Magnetization Prepared Two Rapid Acquisition of Gradient Echoes (ME-MP2RAGE) sequence an...
Jorge Campos Pazmiño, Marc-Antoine Fortin, Véronique Fortier et al.· Magnetic Resonance Imaging· 0 citations
The combination of Strong BGS, water excitation, reference-superimposed processing, and regularized motion correction mitigates motion-related degradation and yields higher-quality perfusion images for high-resolution ASL.
M. Hu, F. Lange, P. Jezzard et al.· medRxiv· 0 citations
BACKGROUND
Free-breathing cardiovascular magnetic resonance (CMR) may provide useful volumetric information. This study evaluated acquisition time and the feasibility of incorporating highly accelerated free-breathing inner-volume balanced T1 relaxation-enhanced steady-state (bT1RESS) imaging into a standard CMR protoc...
R. Edelman, A. Pursnani, M. I. Planek et al.· Journal of Cardiovascular Ma...· 0 citations
BACKGROUND
Neonatal lung diseases such as bronchopulmonary dysplasia (BPD) are currently characterized by clinical observations alone, owing to the lack of safe, non-invasive diagnostic tools for lung structure and function assessment.
OBJECTIVE
This study aims to investigate the feasibility of simultaneous structura...
Xin Miao, HaiThuy N. Nguyen, N. Lee et al.· Pediatric Radiology· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.