Cross-Fidelity Verification of Tuned Mass Damper Design for Slender Steel Chimneys: From 2-DOF to Solid Elements

Oct 2026 · CivilEng · 0 citations

Abstract

A tuned mass damper (TMD) is the standard mitigation for the vortex-induced vibration of steel chimneys, yet it is sized on one low-order model and never checked at higher fidelity. We verify a TMD design for a 60 m steel chimney of 3 m diameter and 5 mm wall (D/t=600) across three fidelities: a Den Hartog absorber, a beam model with a Hirsch ring, and a three-dimensional solid model. They agree to within 0.34% on the first bending frequency and 0.43% on the two Den Hartog modes, and four results follow. On an affordable mesh, fully integrated hexahedra lock and mistune the absorber beyond the tolerance box, costing 32.5% on the peak. Fatigue sizes the device, not the peak response: the customary 3% mass ratio leaves the controlled stress range above the EN 1993-1-9 cut-off, and unlimited life takes about 10%. Across four seismic regions the earthquake does not size the mass, which wind governs through fatigue, but it sizes the stroke: at the two most seismic sites the conventional ring needs 1.6 and 3.3 times the installed clearance, 2.8 and 5.7 once sized for fatigue. Fifteen geometries place the validity limit at (L/D)2/(D/t)≈0.3, below which shell modes precede bending.

Read PDF

Similar papers

Open access Oct 2026

A Numerical Study on the High-Velocity Ballistic Performance of TPMS Sandwich Structures

Triply Periodic Minimal Surface (TPMS) structures have significant potential for lightweight ballistic armor. Unlike previous quasi-static or low-velocity studies, this research explicitly addresses the terminal ballistic regime and perforation morphology. It evaluates three Ti6Al4V TPMS sandwich cores (Diamond, Gyroid...

M. Nguyen, Ba-Anh Le · 0 citations
Open access Oct 2026

Comparative Experimental and Numerical Evaluation of Passive Damping in a Slender Steel Frame

Slender steel frames are flexible and lightly damped, so dynamic actions such as earthquakes and wind can govern their response. Design codes such as ASCE 7 and Eurocode 8 permit the equivalent static (lateral force) procedure only for regular, short-period structures and require dynamic analysis otherwise. This study...

Khaled Ghaedi, Pei Yi Siow, M. Gordan · 0 citations
Open access Oct 2026

Load height effects on lateral torsional buckling of steel beams validated by high-fidelity finite element analysis and code-based design

The lateral-torsional buckling (LTB) behaviour of steel beams is investigated through a combined methodology comprising analytical formulations, code-based beam-element checks, and high-fidelity shell-element linear eigenvalue buckling finite element analysis. Two end-restraint conditions, simple ( k z = k...

Faisal Karim, Mahdieh Safyari, M. Moshtaghi · 0 citations
Open access Oct 2026

Comparative FEM Analysis of Two Beam-Type TMD Sizing Methods Under Motor-Induced Vibrations in a Steel Frame

Industrial steel frames supporting unbalanced motors are susceptible to resonant vibrations that compromise structural safety. While beam-type Tuned Mass Dampers (TMDs) offer a continuous absorber solution, the relative merits of the two primary sizing approaches—the stiffness-driven Maximum Deflection Method (MDM) and...

Carlos N. Zenatti, P. R. Novak, Giovanni Bratti et al. · 0 citations
Conference Open access Sep 2026

Static strength and eight-mode transient screening of a stiffened Q235A steel enclosure under internal pressure

A stiffened Q235A steel enclosure for a coal-mine power monitoring substation is assessed against an adopted differential proof pressure of 1.11 MPa. Manufacturer documents specify a 404 mm x 306 mm x 61 mm enclosure, an approximately 42 kg shell, and an approximately 50 kg complete product. The STEP geometry confirms...

Yan-Ping Sun, Meng-Tao Zhang · 0 citations
Open access Oct 2026

Development of Truss-Type Deployable Mesh Reflector Antenna—Part 2: Design and Ground Verification of 5 m-Scale Mesh Antenna

This study presents the detailed design, structural analysis, assembly, and on-ground verification of a 5 m-scale offset deployable mesh reflector antenna, which represents a scale-up development from a previous 1.5 m-scale design. To mitigate structural vulnerability risks inherent in large-scale configurations, a hig...

Chulhyun Lee, Ryoon-Ho Do, Seunghyun Kim et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.