High-Precision Insulation Monitoring-Driven Intelligent Fault Line Selection Method for Photovoltaic DC Grounding Faults

Aug 2026 · Energies · 0 citations · 24 references

Abstract

Currently, insulation faults in the DC system of photovoltaic (PV) power stations are handled by a full shutdown strategy of inverters, and fault branch localization relies on manual inspection, resulting in low efficiency and poor accuracy, leading to prolonged unplanned outages and substantial power generation losses. This paper proposes an integrated solution combining high-precision insulation monitoring and intelligent fault line selection, which ensures the reliability of line selection criteria through improved measurement accuracy and achieves automatic fault isolation via optimized line selection strategies. The paper analyzes the mathematical essence of the ill-conditioned measurement equations of the traditional bridge method under severe single-pole grounding faults, establishes a dual-channel heteroscedastic noise model, and utilizes the inherent physical constraint that the sum of the positive and negative pole-to-ground voltages always equals the bus voltage to transform the ill-posed inverse problem into an equality-constrained optimal estimation problem, deriving an analytical solution in the sense of constrained least squares. A collaborative monitoring strategy of “balanced bridge monitoring first, unbalanced bridge precision measurement afterward” is proposed. An automatic fault line selection and isolation algorithm based on sequential branch switching is designed, which leverages the operational characteristic that PV systems allow short-term branch interruption, enabling automatic identification and isolation of faulty branches and automatic restoration of non-faulty branches without installing any leakage current sensors. Experimental results show that under severe fault conditions with a single-pole insulation resistance as low as 22 kΩ, the proposed method limits the error to within 5%; the proposed line selection strategy can complete identification and isolation of all faulty branches within at most two rounds of switching.

Read PDF

Similar papers

Open access Sep 2026

Design of a comprehensive protection algorithm for fault detection, classification, and location in high voltage direct current transmission lines connected to wind farms based on local terminal measurements

With the increasing adoption of bipolar high-voltage direct-current (HVDC) transmission lines for wind farm integration, the development of fast, accurate, and communication-independent protection schemes has become a critical technical requirement. This paper proposes a comprehensive protection algorithm within an int...

Mahyar Abasi, Vahid Davatgaran, Morteza Azizi · 0 citations
Open access Sep 2026

Integrated Energy Management and Impedance-Based Fault Protection for Sustainable Renewable DC Microgrids

This paper presents an integrated energy management and protection framework for sustainable renewable DC microgrids. The proposed system combines energy management, fault detection, selective isolation, and impedance-based fault-distance estimation using local voltage and current measurements. The studied 400 V DC mic...

Hafsa El Meskini, M. Azeroual, A. El Amrani et al. · 0 citations
Conference Open access Sep 2026

Decision tree-based fault line selection method for mine power systems using transient polarity and 5th harmonic direction dual criteria

To address the difficulty of single-phase grounding fault line selection in mine resonant grounding systems, this paper proposes a decision tree-based fault line selection method integrating transient polarity and 5th harmonic direction dual criteria. The transient polarity characteristics of zero-sequence currents and...

Jin-Yong Cheng · 0 citations
Open access Aug 2026

Dynamic Fault Detection and Protection Strategies for Medium-Voltage Networks Supplied by Grid-Forming Inverter Sources

In recent years, high penetrations of inverter-based resources are posing significant challenges to the medium-voltage networks, in which protection schemes based on high fault currents and unidirectional power flow may not perform as expected. This paper proposes a dynamic fault-detection and relay-coordination scheme...

Muhammad Abdul Rauf, Munira Batool, I. Madni · 0 citations
Open access Sep 2026

Single-Pole Grounding Fault Protection Method for DC Distribution Networks Based on Instantaneous Feature

DC distribution networks employing a low-current grounding method offer high power supply reliability. However, when a single-pole grounding fault occurs on a feeder, the fault current characteristics are not distinct, making accurate fault identification and feeder protection challenging. Prolonged operation with the...

Wei Jin, Rui-Ya Zhang, Zi-Jie Hu et al. · 0 citations
Open access Sep 2026

Voltage–Current Curve-Based Line Protection for Renewable Energy Systems with Grid-Forming Inverters

The increasing penetration of inverter-based renewable energy resources is reshaping transmission-line fault characteristics and weakening protection criteria designed for synchronous-generator-dominated grids. This paper proposes an internal-fault identification scheme based on voltage–current coupling characteristic...

Long-Fei Ren, Xiao He, Wei-Zhen Li et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.