Oct 2026· Materials and Corrosion· 0 citations· 29 references
Abstract
This study aims to characterize the residual mechanical properties and axial compressive behavior of corroded Q690 steel after fire exposure. Monotonic tensile tests were conducted on specimens subjected to indoor accelerated corrosion followed by high‐temperature exposure. Based on the results, an ABAQUS finite element model of corroded H‐shaped columns was developed for parametric analysis of post‐fire axial compression. Above 600°C, steel exhibits significant mechanical transition: strength degradation accelerates, corrosion effects weaken, and temperature becomes dominant. In contrast, stiffness remains stable, and ductility improves. As slenderness increases, temperature‐induced variation in
α
N
(
D
n
,
T
) diminishes, but corrosion effects persist. Comparisons with current design provisions indicate that existing code curves remain applicable for estimating the post‐fire global stability of corroded Q690 H‐shaped columns when the section properties and residual material parameters are properly updated. These findings support improved post‐fire assessment and repair strategies for corroded steel structures with elastic or limited plastic response.
High-temperature fire exposure can significantly degrade the mechanical properties of high-strength steel, which means utilizing fire-damaged materials remains a critical engineering challenge that requires urgent attention. This study investigates the stress-corrosion characteristics and residual stress evolution of...
Liang Li, Wen-Jiao Dan, Zi-Ran Bao et al.· Journal of materials in civi...· 0 citations
This study investigates the bond behavior of corroded reinforcing bars in reinforced concrete members using beam tests that reproduce stress conditions representative of structural members, complemented by nonlinear finite element (FE) analysis. Thirty‐five specimens were tested, including uncorroded control specimen...
M. Afzal, A. Ferche· Structural Concrete· 0 citations
Fire is one of the most severe accidental actions affecting building structures, and steel elements exposed to high temperatu res may retain load - bearing capacity even after the fire has been extinguished. Since visual inspection alone is insufficient to assess the safety of fire - damaged steel elements, reliable kn...
Roman Červenka, M. Štujberová, T. Klas· Inżynieria Mineralna· 0 citations
Accelerated corrosion tests are widely used to evaluate low‐alloy steels, but whether short‐term laboratory responses can represent long‐term marine atmospheric corrosion remains uncertain. In this study, ten low‐alloy steels were tested under nine cyclic corrosion test (CCT) conditions designed by an L9(3
3
) or...
Fu-Long Wang, Wei Liu, Bo Zhang et al.· Materials and Corrosion· 0 citations
The mechanical degradation of Q420 bridge steel in arid, deicing-salt environments poses a major threat to structural integrity and economy. This study combines experimental and numerical analysis to elucidate the fracture mechanism under combined atmospheric and salt corrosion. Specimens exposed for 0–60 days unde...
Qi-Han Hu, Wen-Jing Qiao, Yi-Qian Li et al.· Journal of materials in civi...· 0 citations
Chloride‐induced corrosion degrades the cross‐section and yield strength of reinforcement, but existing life prediction models often neglect the strength degradation and lack sensitivity analysis. This study developed a service life prediction model for non‐uniformly corroded reinforced concrete members that accounts...