Metal artifact reduction for 3 T MRI-only prostate radiotherapy in patients with hip prostheses: impact on target definition, synthetic CT generation, dose calculation, and fiducial marker identification
The feasibility of an MRI-only radiotherapy workflow at 3 T for prostate cancer patients with hip prostheses is demonstrated, enabling delineation, sCT generation, dose calculation and marker identification from a single MAVRIC-SL acquisition.
Abstract
Magnetic resonance imaging (MRI) offers superior soft-tissue contrast and MRI-only radiotherapy (RT) eliminates uncertainties associated with computed tomography (CT)-to-MRI image registration. An MRI-only RT workflow in patients with hip prostheses remains challenging since delineation, synthetic CT (sCT) generation, and marker identification ideally rely on MR images, which are sensitive to distortions. Metal-artifact reduction sequences (MARS) mitigate metal distortions but often obscure gold markers. The aim of this study is to present a proof-of-concept 3 T MRI-only RT workflow for prostate cancer patients with hip prostheses, using only MARS MAVRIC-SL (GE HealthCare) for delineation, sCT generation and fiducial marker identification. Five prostate cancer patients with one or two hip prostheses and intraprostatic fiducial markers underwent CT, standard 3 T MRI and additional MAVRIC-SL MRI. All images were used retrospectively and did not affect patient treatment. Delineation and sCT generation were performed using MAVRIC-SL. Intraprostatic markers were not visible in MAVRIC-SL due to artifact suppression; instead, raw data were reconstructed into spectral-bin images to manually identify the markers. To prevent incoming radiation from passing through the implants and reduce the associated uncertainties in dose calculation and treatment delivery, beam avoidance sectors (AS) were applied. Conventional CT-based avoidance sectors were registered to the sCT and defined as AS1. Prosthesis-induced signal voids in MAVRIC-SL were used to define AS2. Two treatment plans (42.7 Gy, 7 fractions) were created per patient using AS1 and AS2. Plans were compared using dose-volume histogram (DVH) parameters. AS2-plans were recalculated on registered CTs for DVH-comparison and gamma analyses (2%/2 mm and 1%/1 mm with 10% dose threshold) were performed. Delineation, marker identification and sCT generation were successful using MAVRIC-SL. Median dose differences between AS1 and AS2 remained within ± 0.1% for PTV, while OAR metrics ranged from − 0.4% to + 0.7%. AS2-plans recalculated on CT showed dose differences ≤ 0.9% for PTV and ≤ 1% for OARs. Median gamma pass rates were 99.1% (2%/2 mm) and 96.4% (1%/1 mm). This study demonstrates the feasibility of an MRI-only radiotherapy workflow at 3 T for prostate cancer patients with hip prostheses, enabling delineation, sCT generation, dose calculation and marker identification from a single MAVRIC-SL acquisition. Not applicable.
Abstract Background Computed Tomography (CT) provides geometric accuracy and electron density information essential for radiotherapy planning; however, it offers limited soft‐tissue contrast. Magnetic Resonance Imaging (MRI) improves tumor visualization but introduces registration uncertainties when acquired separately...
P. Ramachandran, Akshay C. Dhargave, Catherine Jones et al.· Journal of Applied Clinical...· 0 citations
Optimize CT acquisition protocols reduced radiation dose while preserving the evaluated objective image quality metrics in the cranial, thoracic, and upper abdominal regions, and was identified as a candidate protocol for subsequent clinical and reader performance validation.
D. Kostova-Lefterova, F. Simeonov, D. Hitova-Topkarova et al.· Biomedical engineering and p...· 0 citations
The motorized attachment for SR3D acquisition reduced image variability and improved image quality, and may encourage broader use of sagittal reconstruction in HDR-BT, potentially improving patient outcomes.
David Contella, Chandima Edirisinghe, Kevin Barker et al.· Brachytherapy· 0 citations
Prostate Imaging Reporting and Data System (PI-RADS) 3 lesions on multiparametric magnetic resonance imaging (mpMRI) represent an equivocal category with an uncertain risk of clinically significant prostate cancer (csPCa), resulting in persistent controversy regarding biopsy indications. Our objective was to evalua...
W. Połom, K. Skrobisz, Anna Połom-Czepek et al.· Polish Journal of Radiology· 0 citations
Objectives: To assess the impact of magnetic resonance imaging (MRI) versus computed tomography (CT) on target delineation and dosimetry in adjuvant vaginal cuff brachytherapy (VBT) for endometrial cancer. Methods: Twenty-five consecutive patients receiving adjuvant high-dose-rate VBT after hysterectomy were prospectiv...
Iustin Pirsan, Aleksandra Winkler, Claudia Gösenbauer et al.· Radiation· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.