Skip to content
Review

Development of an Aptamer-Based Field-Effect Transistor Biosensor for Rapid Detection of Boronophenylalanine (BPA) for Cancer Therapy

Jul 2026 · ECS Meeting Abstracts · Vol MA2026-01, pp. 1577-1577 · 0 citations

TL;DR

This study successfully establishes the fundamental sensing mechanism and validates the stability of the covalent immobilization protocol and provides a solid foundation for translating the technology to complex biological matrices, such as serum and whole blood, for future clinical applications in BNCT.

Abstract

Boron Neutron Capture Therapy (BNCT) relies heavily on the precise accumulation of Boronophenylalanine (BPA) in tumor cells to achieve therapeutic efficacy [1]. However, current clinical methods for monitoring BPA concentrations, such as Inductively Coupled Plasma Mass Spectrometry (ICP-MS), are limited by lengthy analysis times and complex sample pretreatment, rendering them unsuitable for real-time pharmacokinetic monitoring. Furthermore, the development of rapid electrical biosensors is often hindered by probe instability and ionic screening effects in physiological environments [2]. To address these challenges, this study presents a label-free Field-Effect Transistor (BioFET) platform [3] designed for the rapid and specific detection of BPA. A robust surface engineering strategy was employed to ensure optimal probe orientation and stability. The gold sensing gate was first coated with a silicon dioxide (SiO 2 ) layer to facilitate silanization, followed by functionalization with 3-aminopropyltriethoxysilane (APTES) and the heterobifunctional crosslinker SMCC [4, 5]. This approach enables the site-specific covalent immobilization of thiol-terminated BPA aptamers [6], significantly minimizing non-specific desorption compared to physical adsorption methods. Additionally, fluorescently labeled aptamers (FAM-modified) were utilized to visually verify the uniformity of the sensing monolayer. Experimental results in buffer solutions demonstrate that the fabricated BioFET sensor achieves a rapid response time of under 15 minutes with high sensitivity. This study successfully establishes the fundamental sensing mechanism and validates the stability of the covalent immobilization protocol. These findings provide a solid foundation for translating the technology to complex biological matrices, such as serum and whole blood, for future clinical applications in BNCT. REFERENCES Monti Hughes, A. and N. Hu, Optimizing Boron Neutron Capture Therapy (BNCT) to Treat Cancer: An Updated Review on the Latest Developments on Boron Compounds and Strategies. Cancers (Basel), 2023. 15(16). Chu, C.-H., et al., Beyond the Debye length in high ionic strength solution: direct protein detection with field-effect transistors (FETs) in human serum. Scientific reports, 2017. 7(1): p. 1-15. Vu, C.-A. and W.-Y. Chen, Field-effect transistor biosensors for biomedical applications: recent advances and future prospects. Sensors, 2019. 19(19): p. 4214. Hernandez, A. L., et al., Efficient Chemical Surface Modification Protocol on SiO2 Transducers Applied to MMP9 Biosensing. Sensors , 2021. 21(23): p. 8156. Naderlou, E., et al., Enhanced sensitivity and efficiency of detection of Staphylococcus aureus based on modified magnetic nanoparticles by photometrical method. Artificial Cells, Nanomedicine, and Biotechnology, 2020. 48(1): p. 810-817. Hayashi, H., et al., Site-specific aptamer immobilization via amine-to-thiol cross-linking on field-effect transistor biosensor for cortisol detection. Colloids and Surfaces B: Biointerfaces, 2025. 254: p. 114842. Figure 1. (A) Schematic illustration of the BioFET interface engineering. The gold gate is modified with SiO 2 /APTES/SMCC to covalently immobilize BPA-aptamers. (B) Real-time electrical response of the sensor to increasing concentrations of BPA in buffer solution, demonstrating rapid detection within 15 minutes. Figure 1

View source

Similar papers

Aug 2026

Paper-based electrochemical aptasensor using Ti3C2 MXene for sensitive detection of Mammaglobin-A biomarker.

A minimally invasive low-cost paper-based point-of-care electrochemical sensing platform has been developed for early-stage detection of breast cancer and offers significant advantages, including affordability, ease of use, rapid response, and quantitative detection capability.

Jaydeep Kanungo, Somya Sadaf, D. Sharma et al. · 0 citations
Aug 2026

An aptamer-guided flow-cytometric biosensor for simultaneous sizing and polymer identification of nanoplastics.

Nanoplastics are an emerging class of environmental contaminants whose analysis is limited by the difficulty of resolving both particle size and polymer identity at the submicrometre scale in a single high-throughput measurement. Here, a dual-parameter flow-cytometric biosensor was developed that combined polymer-selec...

Hakan Eligul, Murat Kavruk, A. Dursun et al. · 0 citations
Aug 2026

An AuNF-modified optical fiber LSPR biosensor for sensitive and wide-range 5-HT detection.

A label-free, rapid, and cost-effective platform offering a highly promising tool for point-of-care carcinoid screening and neuroendocrine biomarker monitoring, functionalized with in situ grown gold nanoflowers (AuNFs).

Qing-Ze Li, Jiacong Li, Meng-Jie Li et al. · 0 citations
Sep 2026

Synergistic dual-recognition enabled by single-atom nanozyme and aptamer for ultrasensitive colorimetric detection of glyphosate.

While nanozyme-based inhibition strategies are attractive for on-site detection of pesticides, their sensitivity is primarily hampered by insufficient interactions at the nanozyme-pesticide interface. To address this, we developed a dual-recognition system that integrates a Fe/Cu-N-C single-atom nanozyme (SAzyme) with...

Li-Jun Wang, Kun-Rong Zhao, Ming-Hui Luo et al. · 0 citations
Open access Aug 2026

Nanomolecularly imprinted polymer–surface plasmon resonance platform for monitoring trace-level Bisphenol A in drinking water

Bisphenol A is a widespread endocrine-disrupting contaminant frequently detected in aquatic environments, creating a need for rapid and reliable methods for water quality monitoring. Here we show that a solid-phase-synthesized nanomolecularly imprinted polymer (nanoMIP) can be integrated into a surface plasmon resona...

Kadir Erol, Merve İlhan, Ebru Gökmeşe · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.