Skip to content
Conference Open access

Simulation of a Semiconductor Transformerless Dynamic Voltage Restorer with Isolated Phase Inverters

Sep 2026 · 2026 International Russian Automation Conference (RusAutoCon) · pp. 409-414 · 0 citations · 22 references

Abstract

An extensive literature analysis of systems for improving the quality of electricity in smart grids has been conducted, and the problems of industry development have been identified. To solve the problem of effective voltage correction at the load in smart grids, it is proposed to use a transformerless configuration of a voltage booster based on isolated phase inverters connected in series with the load. To investigate the applicability of this technology in Smart Grids, a simulation model of the device has been developed in the Simulink program. The dq transformation with typical PI controllers has been chosen as the basis for the control system. The setup and debugging of the model showed the need for an additional regulator in the zero-sequence circuit, as the proposed device configuration revealed commonmode voltage ripples, which are caused by the lack of galvanic separation between the DC circuit of the voltage booster and the power three-phase network. The simulation of the device's operation demonstrated the high efficiency of correcting voltage drops with an error of less than $\mathbf{0. 1 5 \%}$ and a low THDu of $\mathbf{0. 5 4 \%}$ at the load. During the simulation, the device's limitations were identified, which include fixed power due to the series connection of the output filter inductance of the phase inverters, as well as a slow response to voltage drops, resulting in the inability to compensate for high-frequency interference

Read PDF

Similar papers

Open access 2026

Effect of switching non-linearities on the common mode current in a PV source transformerless inverter in an on-grid system

The integration of solar photovoltaic systems into the grid presents itself with several novel issues that need to be solved before successful integration can be achieved. The problem of common-mode current, also known as leakage current, is one such concern when a trans-formerless system is preferred due to the benefi...

Dilip Kumar Arya, Mohammed Asim, Monauwer Alam et al. · 0 citations
Conference Open access Sep 2026

Research on Voltage Support of Grid-Forming SVG Based on VSG Control Under Weak Grid Conditions

Long transmission lines in remote plateau regions exhibit high impedance, making the point-of-common-coupling (PCC) voltage vulnerable to load disturbances in weak grids. To address this problem, this paper develops a MATLAB/Simulink model comprising an upstream weak grid, line impedance, load, and a grid-forming stati...

Peng-Cheng Zhao, Shi-Rui Yang, Jing Meng et al. · 0 citations
Open access Sep 2026

A New Converter for a Switched Reluctance Generator

This paper proposes a type of converter suitable for switched reluctance generators (SRGs) with a new construction. The new topology of the converter does not require capacitors on the DC bus side and performs AC-AC conversion directly by controlling the generator through phase-to-phase voltage. It can reduce the capac...

Gu-Yuan Ji, Kazuhiro Ohyama · 0 citations
Open access Oct 2026

Self-Supported Transformerless Series Active Power Filter for Wide-Range Load Voltage Compensation

This paper investigates a three-phase transformerless series active power filter based on open-end connections. The studied system was designed to mitigate power quality issues, including voltage harmonics, as well as balanced and unbalanced voltage sags and swells. The topology operates with the fourth wire connected...

Aléssio T. S. S. Santos, C. Jacobina, J. T. Cardoso et al. · 0 citations
Open access Oct 2026

IMPROVING VOLTAGE QUALITY OF AN ON-GRID SOLAR MICROGRID THROUGH DYNAMIC ELECTRIC VEHICLE CHARGING

The paper considers the impact of uncoordinated charging of electric vehicles in residential microgrids with solar generation. It is shown that such charging causes overloading of grid connection lines and unacceptable voltage deviations, while static charging schedules do not make use of surplus generation. A generali...

Bohdan Pashkevych, V. Kalinchyk · 0 citations
Open access Sep 2026

Dynamic simulation and comparative study of custom power devices in distribution feeders for power quality improvement

In the distribution side of electrical power systems, especially in industries, the non-linear and sensitive loads are increasing day by day, due to which the power quality (PQ) is degrading. The main PQ issues are voltage sags, reactive power imbalance, and harmonics, which are primarily addressed by advanced power el...

Tejinder Singh Saggu, Ajay Kumar, Vivek Kumar · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.