Skip to content
Open access

Effect of switching non-linearities on the common mode current in a PV source transformerless inverter in an on-grid system

2026 · Sigma Journal of Engineering and Natural Sciences · 0 citations · 31 references

Abstract

The integration of solar photovoltaic systems into the grid presents itself with several novel issues that need to be solved before successful integration can be achieved. The problem of common-mode current, also known as leakage current, is one such concern when a trans-formerless system is preferred due to the benefits it offers. The issue of leakage current has been addressed in the past, but little to no effort has been made towards analyzing the effect of the non-linear behavior of the semiconductor switches used in power converter circuits. This introduces a gap between theoretical and practical results across all past studies. This paper proposes a mathematical analysis of the various non-linearities present in a transistor switch, which is a novel aspect of transformerless inverter circuit analysis and practical feasibility. The mathematical results define the effect of each non-linearity on the harmonic content and, hence, on the leakage current. A simulation-based study was also conducted, comparing the performance of the practical switch and the ideal switch based on common mode current magnitude and other parameters, including total harmonic distortion, ripple content, and root mean square values of the input and output currents and voltages. It was concluded based on simulation results that the leakage current in the presence of such non-linearities is 10 times higher and total harmonic distortion is 3 times higher than that in their absence for a 1kW system, and the rms values of the output voltage and current are also reduced. The findings suggest that the

Read PDF

Similar papers

Conference Open access Sep 2026

Simulation of a Semiconductor Transformerless Dynamic Voltage Restorer with Isolated Phase Inverters

An extensive literature analysis of systems for improving the quality of electricity in smart grids has been conducted, and the problems of industry development have been identified. To solve the problem of effective voltage correction at the load in smart grids, it is proposed to use a transformerless configuration of...

A. Vyngra, B. Avdeev, Aleksander Sh. Shakiev · 0 citations
Open access 2026

Enhanced Analysis and Optimization of Active-Clamped Forward-Flyback for Highly-Efficient Step-Up Photovoltaic Systems

The Active-Clamped Forward-Flyback is a topology suitable for photovoltaic applications, since it offers high efficiency across wide input/output voltage and power ranges, zero-voltage switching (ZVS) on all the switches and zero-current switching (ZCS) on the secondary side devices, while allowing high power density d...

J. Perez-Martinez, Juan Cruz-Cozar, Cristina Martos-Contreras et al. · 0 citations
Open access Oct 2026

A novel single-stage 5-level inverter based on quasi-z-source with reduced stress on capacitors

The capability of boosting voltage and converting it into alternating current simultaneously and in a single stage is a characteristic of Z-source-based inverters, which makes them attractive. This feature increases system reliability as well as simplifies its design. In this paper, a new single-stage five-level invert...

Pooya Parvizi, Alireza Mohammadi Amidi, Mohammad Reza Zangeneh et al. · 0 citations
Open access Oct 2026

Transformerless nine-level switched capacitor inverter with common-ground for grid-tied PV system

Transformerless multilevel inverters (MLIs) with voltage-boosting capabilities have become an attractive choice for utility grid-connected photovoltaic (PV) systems due to their compactness, high efficiency, and cost-effectiveness. However, leakage current caused by the absence of galvanic isolation remains a major con...

M. Devi, M. Babu · 0 citations
Sep 2026

Comparative Analysis of Commutation Protection Time Effects on Efficiency and Harmonic Distortion in SiC-Based Current Source Inverters

Current Source Inverters (CSIs) offer several unique advantages, such as sinusoidal output voltage and inherent short-circuit protection for high-performance drive applications. However, CSIs using Silicon (Si) IGBTs are constrained by their switching frequencies, necessitating bulky DC-link inductors. Although the Sil...

Kella Srinuprasad, K. Kumar, Darshan R. Iliger et al. · 0 citations
Open access 2026

Mitigation of Dead-Time Effects in the FB-CCV Transformerless PV Inverter

This article analyzes dead-time effects in the full-bridge inverter topology with constant common-mode voltage (FB-CCV) for transformerless grid-connected photovoltaic (PV) applications and proposes a modulation strategy to mitigate the resulting output-voltage distortions, common-mode transients, and power losses. Alt...

Arnaldo O. Cunha, Filipe A. da C. Bahia, J. P. R. A. Méllo et al. · 0 citations