Jan 2026· International Journal of Analytical Chemistry· Vol 2026· 0 citations· 15 references
Medicine
TL;DR
The validated UHPLC‐MS/MS method enables sensitive and reliable quantification of Reg in CRC cells and isolated subcellular fractions and may support future exposure–response assessments beyond plasma‐based pharmacokinetics.
Abstract
Objective Regorafenib (Reg) is a multikinase inhibitor for treating metastatic colorectal cancer (CRC); however, plasma concentrations may not fully predict clinical response. This study aimed to develop and validate an LC‐MS/MS method for quantifying Reg in CRC cells and to preliminarily characterize its temporal and spatial distribution. Methods Separation of Reg and the internal standard (selinexor) was achieved using an Agilent Poroshell 120 EC‐C18 column (3.0 × 100 mm, 2.7 μm) with isocratic elution using acetonitrile and 0.1% aqueous formic acid (70:30, v/v). Detection was performed in multiple reaction monitoring mode using an Agilent 1260‐6460 UHPLC‐MS/MS system. HCT116 and SW480 cells were treated with Reg at their respective IC50 concentrations for 12, 24, 36, and 48 h, and Reg exposure in whole‐cell, nuclear, and mitochondrial fractions was measured. Results The UHPLC‐MS/MS method showed good linearity (R 2 > 0.99) and a lower limit of quantification of 1.0 ng/mL. Precision (intraday RSD% < 11.39%; interday RSD% < 9.11%) and accuracy (RE% within ±6.80%) were within the acceptance criteria. The recovery ranged from 86.03% to 106.41%, and consistent matrix effects were observed. Reg exposure in whole‐cell samples increased in a time‐dependent manner, while nuclear and mitochondrial fraction‐associated exposures showed distinct temporal patterns between the two CRC cell lines. Conclusion The validated UHPLC‐MS/MS method enables sensitive and reliable quantification of Reg in CRC cells and isolated subcellular fractions. The observed temporal differences in intracellular and fraction‐associated Reg exposure may be associated with cellular response and may support future exposure–response assessments beyond plasma‐based pharmacokinetics.
Daraxonrasib, an orally administered pan-RAS inhibitor, is undergoing clinical evaluation for pancreatic ductal adenocarcinoma, colorectal cancer, and non-small cell lung cancer. Defining its pharmacokinetic profile is therefore critical for ongoing progress. Accordingly, a simple and sensitive UPLC-QqQ-MS/MS assay was...
Wen-Tao Zhang, Yan-Zi Liu, Ali Fan et al.· Biomedical chromotography· 0 citations
This validated LC-MS/MS method enables reliable simultaneous quantification of BRAF inhibitors, MEK inhibitors, and CBD in cellular models and provides a valuable tool for investigating intracellular drug concentrations and potential drug–drug interactions affecting intracellular drug levels.
S. Senekowitsch, Katharina Marie Kovalev, Felix Wittig et al.· Pharmaceutics· 0 citations
AIM
A sensitive LC-MS/MS method was developed and validated for the estimation of DM1 fortified with trastuzumab in human serum.
MATERIALS AND METHODS
Quantification was performed in positive mode with protein precipitation extraction using DM4 as an internal standard. Chromatographic separation was achieved using gr...
A. Ghoghari, Harilal V. Patel, Chandrakant Bhatt et al.· Bioanalysis· 0 citations
The clinical development of a sustained-release amlexanox formulation with reduced dosing frequency and improved patient compliance is supported and support the clinical development of a sustained-release amlexanox formulation with reduced dosing frequency and improved patient compliance.
The established LC-MS/MS method provides a reliable alternative to immunoassays, with a wide dynamic range suitable for TDM and personalized dose interval adjustments in patients receiving dupilumab.
Kun-Peng Yang, Jian-Hua Wu, Cheng-Ming Yang et al.· Journal of Pharmaceutical an...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.