Research on the Performance and Regional Applicability of Rural Clean Heating Systems in Jilin Province, China

Oct 2026 · Buildings · Vol 16, pp. 4198 · 0 citations · 36 references

Abstract

Rural heating renovation in Jilin Province requires systems that suit regional conditions while balancing household costs and indoor thermal conditions. This study combined a survey of 276 rural households with TRNSYS multizone simulations to assess five heating configurations in Yanji, Changchun, and Baicheng, China. Survey findings informed case selection, while simulations evaluated energy consumption, indoor temperatures, solar contribution, and life-cycle costs over a 4392 h heating season. Under the adopted operating conditions, floor heating configurations consumed 8.2% less biomass in Yanji and 13.0% less electricity in Changchun than their radiator counterparts. These reductions coincided with lower indoor temperatures and, therefore, reflect differences in complete system configurations and controls, rather than in emitter type alone. In Baicheng, useful solar heat supplied 28.3% of seasonal heat delivery, although biomass remained the principal heat source during the coldest months. Discounted costs over 15 years ranged from USD 5411 to USD 11,127, and sensitivity analysis identified relative installation costs as a key determinant of economic rankings. By linking household survey evidence with energy, economic, and hourly temperature assessments, this study provides a basis for regional heating decisions that account for local energy availability, household costs, and the indoor conditions provided.

Read PDF

Similar papers

Open access Sep 2026

Research on Energy-Saving Renovation of Building Envelope Structures in Rural Areas of Central Plains of China

Rural residential buildings in China’s Central Plains region suffer from poor envelope thermal performance, resulting in severe thermal discomfort and excessive energy consumption for both winter heating and summer cooling. This study presents a systematic three-in-one envelope retrofit strategy (roof, exterior walls,...

Wen-Tao Liu, Qing-Bo Hu · 0 citations
Open access Sep 2026

Analysis of district heating and heat pump application at the level of a typical non-renovated multi-apartment building

The study evaluates the feasibility of integrating air­to­water heat pump systems into a non­renovated multi­apartment building connected to a district heating network. The research is based on real annual heat consumption data (471.82 MWh) and dynamic modelling performed using the EnergyPRO software. A baseline distri...

Lukas Danielius Lukša, Giedrė Streckienė · 0 citations
Open access Nov 2026

Performance Assessment of Solar Thermal Systems with Heat Storage in Multifamily Buildings Under Real Climatic Conditions

This study evaluates the long - term performance of a solar thermal system coupled with thermal energy storage (TES) for a reference multifamily building in northeastern Poland using 14 consecutive years (2010 – 2023) of hourly PVGIS - SARAH3 meteorological data . The reference building comprises 16 dwellings and 48 oc...

Yurii Furdas, M. Adamski, Leszek Bargłowski et al. · 0 citations
Open access Oct 2026

Non-evaporative district cooling cuts costs, saves water, and eases grid pressure in tropical cities

Tropical coastal regions face rapidly growing cooling demand, increasing pressure on electricity systems and freshwater resources. Conventional water-cooled chillers are energy- and water-intensive, exacerbating grid vulnerability and water scarcity under hot, humid conditions. Here we present a comparative techno-econ...

H. Oh, Jeff Winick, J. Coony et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.